Affiliation:
1. Safety in Mines Research Establishment Sheffield.
Abstract
The entrainment of air into a conical spray centred on the axis of a short tube is investigated. Dimensional analysis successfully correlates the experimental results of both the present and previous investigations for the case of an unrestricted system. The case where the spray operates against a back pressure, such as might be represented by a length of ducting connected to the outlet, is also considered. Morton's analysis of entrainment into the wake of an isolated body is adapted and some agreement is obtained with experimental results for small flight distance of the drops.
Cited by
8 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献