Use of a smartwatch for home blood pressure measurement
-
Published:2023-07-30
Issue:
Volume:
Page:10-16
-
ISSN:2444-4987
-
Container-title:Journal of Research and Development
-
language:en
-
Short-container-title:JRD
Author:
MEX-ÁLVAREZ Rafael Manuel de Jesús1, GUILLEN-MORALES María Magali1, YANEZ-NAVA David1, NOVELO-PÉREZ María Isabel1
Affiliation:
1. Universidad Autónoma de Campeche
Abstract
The use of smart watches represents an advantage in home monitoring of ambulatory patient blood pressure; but it is necessary to know the degree of correspondence with the conventional equipment for a better control of the blood pressure that is of clinical utility, in the present study the correlation of the values of the blood pressure obtained by a digital baumanometer and by a watch was evaluated. intelligent in young males at rest and after exercise; the results obtained show a good correlation between the measurements obtained by both teams (R2 values greater than 0.7), the cautious use of smart watches is useful for better monitoring of blood pressure and presents advantages such as automatic and digital recording of the values that can be used for ambulatory blood pressure monitoring.
Subject
Pharmacology (medical)
Reference24 articles.
1. 1. Fuentes, R., & Bañuelos, M. A.. (2004). Digital blood pressure monitor. Journal of applied research and technology, 2(3), 224-229. 2. 2. González-Rivas, J. P. (2016). Optimizando la medición de la presión arterial en la consulta. Revista Venezolana de Endocrinología y Metabolismo, 14(3), 179-186. 3. 3. Galván-Oseguera, H., Rosas-Peralta, M., Borrayo-Sánchez, G., González-Díaz, B.E., Almeida-Gutiérrez, E., Ramírez-Arias, E., & Pérez-Rodríguez, G. (2019). Formas de medición de la presión arterial sistémica: el debate continúa. Medicina interna de México, 35(1), 104-112. https://doi.org/10.24245/mim.v35i1.2458 4. 4. Bhanvadia, S.B., Manreet S.B., Arash Delavar, K.T., Bharanidharan, R., Saseendrakumar, R.N., Weinreb, L.M.Z., & Sally, L.B. (2022). Assessing Usability of Smartwatch Digital Health Devices for Home Blood Pressure Monitoring among Glaucoma Patients" Informatics, 9(4), 79. https://doi.org/10.3390/informatics9040079 5. 5. Cardona-Müller, D., Grover-Páez, F., Guzmán-Saldivar, V., Alanis-Sánchez, G.A., Murguía-Soto, C., Totsuka-Sutto, S.E., Quezada-Fernández, P., Macías-Chumacera, A., Cardona-Muñoz, E.G., & Ramos-Becerra, C.G. (2018). Confiabilidad de un monitor automatizado para la medición de la presión arterial. Revista médica de Chile, 146(2), 190-195. https://dx.doi.org/10.4067/s0034-98872018000200190
|
|