Abstract
The relevance of using compensated induction machines in the generator mode of autonomous power supply systems is determined by their ability to provide a stable and reliable power supply even in the absence of an external grid. The research aims to develop a procedure for determining the characteristics of an equivalent circuit of compensated induction generators that considers the mutual influence between the main and additional phase windings of the armature. The theory of an idealised induction machine with the representation of electromechanical energy conversion processes and basic physical parameters in the form of equations of electrical equilibrium and drive motion was used to obtain the calculated characteristics of the generator’s operating modes of this class. The generalised system of differential equations made it possible to calculate dynamic and static processes for symmetrical and asymmetrical modes at given machine parameters under different methods of excitation and voltage stabilisation under variable load. For the practical implementation of modelling the parameters of an induction generator, the equations of electrical equilibrium of the stator and rotor circuits for the symmetrical steady-state mode are used, which is a special case of the generalised mathematical model of the machine for both transient and steady-state processes with constant parameters of the substitution scheme. Consideration of the structural and functional features of compensated induction generators was made possible by using a mathematical model with the armature winding divided into two coaxial or spatially offset half-windings. In this case, the number of calculation equations doubles. The use of an autotransformer scheme for switching on the stator phase half-windings to capacitors required the introduction of an additional differential equation for the electrical equilibrium of the stator phases. This made it possible to substantiate the values of active and inductive resistances used in the replacement circuit of an induction generator with internal capacitive reactive power compensation. The mutual inductive coupling of the main and additional half-windings of the generator stator phase windings due to both the operating magnetic flux and the magnetic fluxes of dissipation was considered. The practical significance of the obtained results is to increase the efficiency and stability of the power supply, which helps to reduce losses and improve the operation of electric power systems
Publisher
National University of Life and Environmental Sciences of Ukraine
Reference20 articles.
1. [1] Al-Jufout, S., Al-rousan, W., & Wang, C. (2018). Optimization of induction motor equivalent circuit parameter estimation based on manufacturer’s data. Energies, 11(7), article number 1792. doi: 10.3390/en11071792.
2. [2] Boldea, I., & Nasar, S.A. (2009). The induction machines design handbook (2nd ed.). Boca Raton: CRC Press. doi: 10.1201/9781315222592.
3. [3] Chuenko, R.M., & Kryvoshey, O.A. (2014). Determination of the parameters of the replacement scheme of the compensated asynchronous motor. Scientific Bulletin of the National University Environment and Science of Ukraine. Series: Agricultural Machinery and Energy, 194(3), 265-270.
4. [4] Ferrucho-Alvarez, E.R., Martinez-Herrera, A.L., Cabal-Yepez, E., Rodriguez-Donate, C., Lopez-Ramirez, M., Mata-Chavez, R.I. (2021). Broken rotor bar detection in induction motors through contrast estimation. Sensors, 21, article number 7446. doi: 10.3390/s21227446.
5. [5] Helonde, A.R., & Mankar, M.M. (2019). Identifying three phase induction motor equivalent circuit parameters from nameplate data by different analytical methods. International Journal of Trend in Scientific Research and Development, 3(3), 642-645. doi: 10.31142/ijtsrd22934.