Comparative evaluation of biting force in 2mm locking plates with 2mm miniplates in the treatment of mandible fractures: A clinical study

Author:

Soujanya V Shakuntala1,Reddy Abhishek2,Kranthi K,Pantham Dilip,Keerthi P Durga

Affiliation:

1. M

2. Meghna Institute of Dental Sciences, Nizamabad, Telangana, India

Abstract

1. To compare efficacy of 2mm locking plates with 2mm miniplates in the fixation of mandible fractures and 2. To evaluate and compare the biomechanical function by measuring the bite force at 1st week, 3rd week, 6th week and 3rd month postoperatively in 20 patients divided equally into two study groups.A prospective randomized study was carried out at Department of Oral and Maxillofacial Surgery, Meghna Institute of Dental Sciences, Nizamabad from 2019 to 2021 to treat consecutive mandibular fractures where patients were randomly divided into two groups each composed of 10 patients where Group A were treated with single 4 holed stainless-steel locking miniplates and Group B with two 4 holed stainless steel conventional mini plates both maintaining a gap of 2.0 mm system. Later assessment was done using bite force recording postoperatively at 1st week, 3rd week, 6th week and 3rd month and with the associated complications like Swelling, Infection, Paresthesia, Mobility between fracture fragments and Hardware failure.When the mean bite force values in right molar region of group A and group B were compared at 1st week, 3rd week, 6th week and 3rd month, there was statistically significant increase in bite force noted in group A when compared to group B at 1st week and 3rd week (P<0.05). But no statistically significant differences were observed at 6th week and 3rd month (P>0.05).When the mean bite force values in the central incisor region of group A and group B were compared at 1st week, 3rd week, 6th week and 3rd month, there was statistically significant increase in bite force noted in group A compared to group B at 1st week and 3rd week (P<0.05). But no statistically significant differences were observed at 6th week and 3rd month (P>0.05).When the mean bite force values in left molar region of group A and group B were compared at 1st week, 3rd week, 6th week and 3rd month, there was statistically significant increase in bite force noted in group A when compared group B at 3rd week (P<0.05). But no statistically significant differences were observed at 1st week, 6th week and 3rd month (P>0.05).The study signifies that both the fixation systems were able to provide stability to fracture segments, but locking plate system has provided better stability when compared to miniplates system, hence recommending for more elaborative studies to arrive at definitive conclusion.

Publisher

IP Innovative Publication Pvt Ltd

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3