IOP change after phacoemulsification with PCIOL implantation and its association with ocular biometric parameters

Author:

Rahman Sharah,Ahmed Jalal,Rahman Anisur,Anwar Ishtiaque,Zafrullah Tarzia Asma,Mitu Sharifa Zahan,Chowdhury Mahziba Rahman,Ul Kadir Syeed Mehbub

Abstract

: To assess the impact on intraocular pressure (IOP) after Phacoemulsification (PE) with Posterior Chamber Intraocular Lens (PCIOL) implantation and its relation with ocular biometric parameters. The study was a prospective observational study included 524 eyes with normal IOP (11-21 mmHg) who underwent uneventful Phacoemulsification with PCIOL Implantation surgery for age-related cataract. IOP, Central Corneal Thickness (CCT), Anterior Chamber Depth (ACD), Axial Length (AL) were measured pre-operatively and one month post-operatively by Goldman Applanation Tonometer, Corneal Pachymeter and Optical Coherence Biometer, respectively. The post-operative IOP change and its relation with preoperative biometric parameters were determined.: The mean pre-operative and post-operative IOP was 13.44±1.98 & 11.54±1.66mmHg, respectively, with an average IOP reduction after one month of 1.90±0.61mmHg. The mean pre-operative and post-operative ACD was 3.27±0.24 and 3.66±0.27 mm, respectively, with an average increase of 0.39 ±0.3 mm. Paired t-test showed post-operative IOP reduction was significantly associated with preoperative IOP (p<0.001) and ACD (p<0.001). But CCT and AL were not significantly associated. The linear regression analysis confirmed the proportional reduction of post-operative IOP, r 0.921. So 92.1% of the preoperative IOP is proportional to post-operative IOP reduction. The graphical representation shows more the pre-operative IOP, more the post-operative IOP reduction.: IOP is significantly reduced, and ACD increased after PE with PCIOL implantation surgery and is associated with post-operative IOP reduction. The post-operative IOP reduction is proportional to pre-operative IOP, and more the preoperative IOP, more the post-operative IOP reduction.

Publisher

IP Innovative Publication Pvt Ltd

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3