Accuracy and predictability of novel MS Excel-based surgically induced astigmatism calculator

Author:

Prabhakar S K1ORCID,Middha Oshin2,George Feba Mary,Kothak Uditi Pankaj,Yadav Prashansa

Affiliation:

1. Academy of Higher Education and Research, Mysore, Karnataka, India

2. A

Abstract

Study of steepening, flattening, clockwise, and counter-clockwise torque effect is indispensable to understand and design surgical induced astigmatism calculator. Hence, in this study by constructing a novel Microsoft Office Excel 2007 based astigmatic calculator following cataract surgery, analysis on the accuracy and predictability evaluated for the performance. Post-cataract surgery patients from May 2019 to January 2020 at a tertiary medical institution recruited for this present study. Based on Pythagoras principle, MS Excel calculator designed and the law of cousins for calculating the vector magnitude and axis respectively. Manual keratometry measurements for pre and postoperative horizontal (Kh) and vertical (Kv) curvatures established, and statistical analysis for the resultant SIA magnitude and axis deduced with Medcalc software comparing with the existing SIA 2.1 version calculator. A total of 29 eyes of 25 patients studied with a mean age of 62.55 (±8.08) years, males contributing to 14 (56%), and right laterally in 17 (58%) eyes. MS Excel and SIA 2.1 versions calculated a mean SIA magnitude of 0.66 (±0.47) D and 0.64 (±0.55) D respectively. Pearson coefficient correlation (r=-0.16, p=0.40), paired-two sample test (t value= 0.11, p= 0.91) and ROC curve analysis (AUC = 0.75, p= 0.34, 95% CI= 0.25 to 0.99) calculated. Regression equation (y = 0.75 + -0.14 x) and limits of agreements (95% CI -0.29 to 0.31) analyzed, and, 95% of data points distributed within ±1.96 SD of the line of equality on Bland-Altman difference plots.The present calculator proclaimed an acceptable accuracy and agreement with a prediction of 0.61 Diopter for every unit change in the magnitude of SIA 2.1 software in addition to consideration of interchangeability.

Publisher

IP Innovative Publication Pvt Ltd

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3