Effects of Lateral Eye Displacement on Comfort While Reading from a Video Display Terminal

Author:

Haynes Malcolm1,Starner Thad2

Affiliation:

1. United States Military Academy, West Point, New York, malcolm

2. Georgia Institute of Technology, NW, Atlanta, Georgia

Abstract

Some small field-of-view (FOV) head worn displays (HWD), like Epson's Moverio BT-300, are mounted directly in the user's line of sight. In contrast, Google Glass is mounted “out of the way” and above the line of sight. Other displays like the Vuzix M100 or Optinvent ORA-1 allow the user to adjust the display position, and some users have expressed a desire for the display to be laterally displaced toward the ear, out of the main line of sight. How far toward the ear can a small FOV display be mounted and still be used comfortably? Using a 30-minute reading task and an emulated display with the FOV of a typical smart phone (9.2°x 16.3°), we study a user's perceived comfort level while reading at four horizontally displaced positions. We ask participants to rate their comfort every five minutes using a 5-point Likert scale knob (5 being most comfortable), for a total of seven measurements. Scores are summed over the seven measurements to form a summed comfort score. We find that 0° (Md = 34.0; p«0.001), 10° (Md = 33.5; p«c0.001), and 20° (Md = 33.5; p«c0.001) are more comfortable than 30° (Md = 29.5) and that 0° (p<0.01) and 10° (p<0.01) are more comfortable than 20°. Reading performance and workload measures were numerically similar across all conditions. Given the main results of the experiment, post-hoc analysis on other measurements such as preference and asthenopia, and participant comments, we suggest that small FOV displays should be mounted at lateral displacement angles of 20° and less for sustained use.

Publisher

Association for Computing Machinery (ACM)

Subject

Computer Networks and Communications,Hardware and Architecture,Human-Computer Interaction

Reference27 articles.

1. Saber Abdi and Agneta Rydberg. 2005. Asthenopia in schoolchildren orthoptic and ophthalmological findings and treatment. Documenta ophthalmologica 111 2 (2005) 65--72. Saber Abdi and Agneta Rydberg. 2005. Asthenopia in schoolchildren orthoptic and ophthalmological findings and treatment. Documenta ophthalmologica 111 2 (2005) 65--72.

2. Yuliya Bababekova Mark Rosenfield Jennifer E Hue and Rae R Huang. 2011. Font size and viewing distance of handheld smart phones. Optometry 8 Vision Science 88 7 (2011) 795--797. Yuliya Bababekova Mark Rosenfield Jennifer E Hue and Rae R Huang. 2011. Font size and viewing distance of handheld smart phones. Optometry 8 Vision Science 88 7 (2011) 795--797.

3. Yoav Benjamini and Yosef Hochberg. 1995. Controlling the false discovery rate: a practical and powerful approach to multiple testing. Journal of the royal statistical society. Series B (Methodological) (1995) 289--300. Yoav Benjamini and Yosef Hochberg. 1995. Controlling the false discovery rate: a practical and powerful approach to multiple testing. Journal of the royal statistical society. Series B (Methodological) (1995) 289--300.

4. Dinesh J Bhanderi Sushilkumar Choudhary Vikas G Doshi etal 2008. A community-based study of asthenopia in computer operators. Indian journal of ophthalmology 56 1 (2008) 51. Dinesh J Bhanderi Sushilkumar Choudhary Vikas G Doshi et al. 2008. A community-based study of asthenopia in computer operators. Indian journal of ophthalmology 56 1 (2008) 51.

5. Eric J Borsting Michael W Rouse G Lynn Mitchell Mitchell Scheiman Susan A Cotter Jeffrey Cooper Marjean Taylor Kulp Richard London Convergence Insufficiency Treatment Trial Group et al. 2003. Validity and reliability of the revised convergence insufficiency symptom survey in children aged 9 to 18 years. Optometry 8 Vision Science 80 12 (2003) 832--838. Eric J Borsting Michael W Rouse G Lynn Mitchell Mitchell Scheiman Susan A Cotter Jeffrey Cooper Marjean Taylor Kulp Richard London Convergence Insufficiency Treatment Trial Group et al. 2003. Validity and reliability of the revised convergence insufficiency symptom survey in children aged 9 to 18 years. Optometry 8 Vision Science 80 12 (2003) 832--838.

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Looking From a Different Angle: Placing Head-Worn Displays Near the Nose;Proceedings of the Augmented Humans International Conference 2024;2024-04-04

2. CASES;Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies;2023-09-27

3. 65-2: Sensitivity to Peripheral Artifacts in VR Display Systems;SID Symposium Digest of Technical Papers;2018-05

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3