Affiliation:
1. Hewlett-Packard Labs., Palo Alto, CA
Abstract
Configuring redundant disk arrays is a black art. To configure an array properly, a system administrator must understand the details of both the array and the workload it will support. Incorrect understanding of either, or changes in the workload over time, can lead to poor performance. We present a solution to this problem: a two-level storage hierarchy implemented inside a single disk-array controller. In the upper level of this hierarchy, two copies of active data are stored to provide full redundancy and excellent performance. In the lower level, RAID 5 parity protection is used to provide excellent storage cost for inactive data, at somewhat lower performance. The technology we describe in this article, know as HP AutoRAID, automatically and transparently manages migration of data blocks between these two levels as access patterns change. The result is a fully redundant storage system that is extremely easy to use, is suitable for a wide variety of workloads, is largely insensitive to dynamic workload changes, and performs much better than disk arrays with comparable numbers of spindles and much larger amounts of front-end RAM cache. Because the implementation of the HP AutoRAID technology is almost entirely in software, the additional hardware cost for these benefits is very small. We describe the HP AutoRAID technology in detail, provide performance data for an embodiment of it in a storage array, and summarize the results of simulation studies used to choose algorithms implemented in the array.
Publisher
Association for Computing Machinery (ACM)
Reference58 articles.
1. BURKES. T. D~MOND B. AND Vomw D. 1995. Adaptive hierarchical RAID: A solution to the RAID 5 write problem. Part No. 5963-9151 Hewlett-Packard Storage Systems Division Boise Idaho.]] BURKES. T. D~MOND B. AND Vomw D. 1995. Adaptive hierarchical RAID: A solution to the RAID 5 write problem. Part No. 5963-9151 Hewlett-Packard Storage Systems Division Boise Idaho.]]
2. The TickerTAIP parallel RAID architecture
Cited by
167 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
1. Data management of scientific applications in a reinforcement learning-based hierarchical storage system;Expert Systems with Applications;2024-03
2. Storage Arrays;Data Storage Architectures and Technologies;2024
3. Network Storage Architectures;Data Storage Architectures and Technologies;2024
4. Elastic RAID: Implementing RAID over SSDs with Built-in Transparent Compression;Proceedings of the 16th ACM International Conference on Systems and Storage;2023-06-05
5. Reliability Stripe Coagulation in Two Failure Tolerant Storage Arrays;2023 International Conference on Communication System, Computing and IT Applications (CSCITA);2023-03-31