National Trends in Utilization and 1-Year Outcomes with Transplantation of HCV-Viremic Kidneys

Author:

Potluri Vishnu S.,Goldberg David S.,Mohan SumitORCID,Bloom Roy D.ORCID,Sawinski Deirdre,Abt Peter L.,Blumberg Emily A.,Parikh Chirag R.,Sharpe James,Reddy K. Rajender,Molnar Miklos Z.ORCID,Sise Meghan,Reese Peter P.

Abstract

BackgroundRecent pilot trials have demonstrated the safety of transplanting HCV-viremic kidneys into HCV-seronegative recipients. However, it remains unclear if allograft function is impacted by donor HCV-viremia or recipient HCV-serostatus.MethodsWe used national United States registry data to examine trends in HCV-viremic kidney use between 4/1/2015 and 3/31/2019. We applied advanced matching methods to compare eGFR for similar kidneys transplanted into highly similar recipients of kidney transplants.ResultsOver time, HCV-seronegative recipients received a rising proportion of HCV-viremic kidneys. During the first quarter of 2019, 200 HCV-viremic kidneys were transplanted into HCV-seronegative recipients, versus 69 into HCV-seropositive recipients, while 105 HCV-viremic kidneys were discarded. The probability of HCV-viremic kidney discard has declined over time. Kidney transplant candidates willing to accept a HCV-seropositive kidney increased from 2936 to 16,809 from during this time period. When transplanted into HCV-seronegative recipients, HCV-viremic kidneys matched to HCV-non-viremic kidneys on predictors of organ quality, except HCV, had similar 1-year eGFR (66.3 versus 67.1 ml/min per 1.73 m2, P=0.86). This was despite the much worse kidney donor profile index scores assigned to the HCV-viremic kidneys. Recipient HCV-serostatus was not associated with a clinically meaningful difference in 1-year eGFR (66.5 versus 71.1 ml/min per 1.73 m2, P=0.056) after transplantation of HCV-viremic kidneys.ConclusionsBy 2019, HCV-seronegative patients received the majority of kidneys transplanted from HCV-viremic donors. Widely used organ quality scores underestimated the quality of HCV-viremic kidneys based on 1-year allograft function. Recipient HCV-serostatus was also not associated with worse short-term allograft function using HCV-viremic kidneys.

Funder

Health Resources and Services Administration

Publisher

American Society of Nephrology (ASN)

Subject

Nephrology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3