Dialysis unit and patient characteristics associated with reuse practices and mortality: 1989-1993.

Author:

Collins A J,Ma J Z,Constantini E G,Everson S E

Abstract

The diverse patient and dialysis unit characteristics in the United States pose challenges for assessing the safety and efficacy of reuse practices. A 10% random sample of period-prevalent hemodialysis patients from units practicing conventional dialysis (<25% of patients with high-efficiency/high-flux dialysis) were analyzed. The data included 13,926 patient observations in 1989-1990 and 20,422 in 1991-1993. Centers for Disease Control and Prevention and Health Care Financing Administration facility survey Medicare data were analyzed with a Cox regression model, evaluating the risk of reuse compared with no reuse and adjusting for comorbidity, unit characteristics, and profit status. In 1989-1990, freestanding and hospital-based units that did not reuse dialyzers were not significantly different from each other in mortality rates. In 1991-1993, however, no-reuse, freestanding, for-profit units had higher risks (relative risk [RR] = 1.23, P = 0.003) compared with no-reuse, hospital-based, nonprofit units. No-reuse, hospital-based, for-profit units, in contrast, were associated with a lower mortality risk (RR = 0.70, P = 0.0001). An isolated higher risk associated with peracetic acid manual reuse in freestanding units (1989-1990) was identified in for-profit units only. In the 1991-1993 period, an increased mortality risk was noted in hospital-based, nonprofit units practicing formaldehyde automatic reuse, and in freestanding, for-profit units using glutaraldehyde, which accounted for <5% of all units. All other interactions of reuse germicide and technique were not different from no-reuse. The varying mortality rates identified in both no-reuse and reuse units using conventional dialysis suggest that other factors, such as dialysis therapy and anemia correction (both known predictors of patient survival), have a greater influence on U.S. mortality than reuse germicides and techniques.

Publisher

American Society of Nephrology (ASN)

Subject

Nephrology,General Medicine

Cited by 38 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Dialyzer reprocessing: Considerations and pitfalls for effective and safe hemodialysis;Seminars in Dialysis;2023-06-15

2. Reprocessing of hemodialyzers;ANSI/AAMI RD47:2020; Reprocessing of hemodialyzers;2019-12-23

3. Early Trends From the Study to Evaluate the Prospective Payment System Impact on Small Dialysis Organizations (STEPPS);American Journal of Kidney Diseases;2013-06

4. Dialyzer Reprocessing;Modelling and Control of Dialysis Systems;2013

5. Dialyzer Reuse and Mortality Risk in Patients with End-Stage Renal Disease: A Systematic Review;American Journal of Nephrology;2012

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司