Anastomotic intimal hyperplasia in prosthetic arteriovenous fistulas for hemodialysis is associated with initial high flow velocity and not with mismatch in elastic properties.

Author:

Hofstra L,Bergmans D C,Leunissen K M,Hoeks A P,Kitslaar P J,Daemen M J,Tordoir J H

Abstract

Stenotic intimal thickening at the venous end of prosthetic arteriovenous (AV) fistulas for hemodialysis has been associated with perianastomotic mismatch in elastic properties, and low shear rates. In a prospective way, the role of these factors on the occurrence of intimal hyperplasia in prosthetic AV fistulas in hemodialysis patients was investigated. In 24 hemodialysis patients, the elastic properties were assessed in the distal graft segment and the outflow vein postoperatively with the use of Vessel Wall Doppler Tracking (VWDT), a noninvasive ultrasound technique. In addition, normalized peak systolic velocity (nPSV) was calculated from diameter (VWDT) and peak systolic velocity. The initial mismatch around the venous anastomoses and local nPSV were correlated with the occurrence of stenoses during follow-up (2 yr). The detection of a stenosis was performed with both Duplex ultrasound and angiography. In four cases, a stenosis developed in the venous anastomosis; in eight cases, a stenosis developed in the venous outflow segment; and in four cases, stenoses developed at both sites. A better initial match in elastic properties around the venous anastomosis was observed in the fistulas developing a stenosis at this site as compared with the nonstenotic fistulas (P < 0.05). The initial local nPSV values at the site of the later stenosis were higher in the fistulas developing a stenosis as compared with the nonstenotic fistulas (P < 0.05). It was concluded that the occurrence of stenoses in prosthetic AV fistulas for hemodialysis in or adjacent to the venous anastomoses is associated with a high initial flow velocity but not with a mismatch in elastic properties.

Publisher

American Society of Nephrology (ASN)

Subject

Nephrology,General Medicine

Cited by 36 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3