A comparison of three brands of polysulfone membranes.

Author:

Hoenich N A,Woffindin C,Brennan A,Cox P J,Matthews J N,Goldfinch M

Abstract

A prospective clinical crossover study comparing the functional performance and biocompatibility of three brands of polysulfone membranes (Fresenius Polysultone (Fresenius Ag, Bad Homburg, Germany), Polyphen (Minntech Corp., Minneapolis, MN), and Biosulfane (WR Grace Inc., Danvers, MA)) incorporated in ethylene oxide-sterilized dialyzers of comparable surface area (1.3 to 1.35 m2) was undertaken. The clearance of small molecules by each membrane was comparable. Plasma levels of beta 2 microglobulin fell to 49.9% of pretreatment values by 210 min when using the Fresenius Polysulfone membrane, 60.2% with the Polyphen membrane, and 63.1% with the Biosulfane membrane. The reduction achieved by the Fresenius Polysulfone membrane was superior (P = 0.003). The plasma reductions were associated with the recovery of 195 mg beta 2 microglobulin from the dialysate for the Fresenius Polysulfone membrane and 158 mg for the Polyphen membrane, but no beta 2 microglobulin was recovered from the dialysate with the Biosulfane membrane. The dialysate collected with the Fresenius Polysulfone membrane also contained a mean of 6853 mg of total protein, compared with 5490 mg with the Polyphen membrane and 8422 mg with the Biosulfane (P = 0.04) membrane. The neutropenia was slight and independent of membrane brand, as were the changes in C3a des arg and SC5b-9 complement components. The reduction in platelet counts was higher for the Biosulfane membrane than for the other brands (P = 0.003). This study indicates that whereas the polymer base of the membrane is the same, its production and subsequent handling during dialyzer production induce changes that attain statistical significance, most notably in the way that the membrane removes beta 2 microglobulin and interacts with proteins. The differences observed are a consequence of the different alloying polymers used during manufacture and, consequently, the membranes cannot be considered equivalent.

Publisher

American Society of Nephrology (ASN)

Subject

Nephrology,General Medicine

Cited by 21 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3