Comparing Low Volume Versus Conventional Volume of Polyethylene Glycol for Bowel Preparation during Colonoscopy: A Randomised Controlled Trial

Author:

Othman Muhammad Faeid, ,Zakaria Andee Dzulkarnaen,Yahya Maya Mazuwin,Md Hashim Mohd Nizam,Wan Mokhter Wan Mokhzani,Wan Zain Wan Zainira,Mohamad Ikhwan Sani,Mohd Shah Mohd Shahrulsalam,Syed Abd Aziz Syed Hassan,Nik Ab Kadir Mohd Nasrullah,Zakaria Zaidi,Wong Michael Pak-Kai, , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,

Abstract

Background: Polyethylene glycol (PEG) solution is widely used as a colonoscopic bowel cleaning agent, although some patients are intolerant due to the need for ingesting large solution volumes and unpleasant taste. A low-volume solution may enhance patient tolerability and compliance in bowel preparation. Accordingly, this study compared the effectiveness of two difference PEG volumes for bowel preparation before colonoscopy in terms of bowel cleanliness, completeness of colonoscopy, patient tolerability and colonoscopy duration. Methods: Using a prospective randomised controlled single-blinded study design, 164 patients scheduled for colonoscopy were allocated to two groups (n = 82 patients in each) to receive either the conventional PEG volume (3 L, control group) or the low volume (2 L, intervention group). The Boston Bowel Preparation Scale (BBPS), a validated scale for assessing bowel cleanliness during colonoscopy, was used to score bowel cleanliness in three colon segments. Secondarily, colonoscopy completeness, tolerability to drinking PEG and the duration of colonoscopy were compared between the groups. Results: There were no statistically significant differences between the two intervention groups in terms of bowel cleanliness (P = 0.119), colonoscopy completion (P = 0.535), tolerability (P = 0.190) or the amount of sedation/analgesia required (midazolam, P = 0.162; pethidine, P = 0.708). Only the duration of colonoscopy differed between the two groups (longer duration in the control group, P = 0.039). Conclusion: Low-volume (2 L) PEG is as effective as the standard 3 L solution in bowel cleaning before colonoscopy; however, the superiority of either solution could not be established.

Publisher

Penerbit Universiti Sains Malaysia

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3