Immediate Weight Bearing After Fixation of Humeral Shaft Fractures with Small Fragment Hybrid Plating: A Biomechanical Analysis

Author:

Bledsoe J. Gary1,Geraud Simone2,Cannada Lisa K.3

Affiliation:

1. Saint Louis University School of Engineering, Saint Louis, MO

2. UPMC Hamot, Erie, PA

3. Novant Health, Hughston Clinic, Jacksonville, FL

Abstract

Background This study evaluates the stiffness of both 4.5 mm dynamic compression plates (DCP) and 3.5 mm hybrid locking-compression plates (LCP) for treatment of humeral shaft fractures in a simulated weight bearing model. Methods Testing was performed on 16 4th generation Sawbones humeri. Initial axial and torsional stiffness were determined. Plates were placed and a 5 mm defect was produced. Specimens were subjected to 90,000 loading cycles to simulate 90 days of crutch walking and then loaded to failure. Statistical analysis was performed using a t-test with significance at P < 0.05. Findings Comparison reveals a significant difference between the intact axial and torsional stiffness of 4.5 mm DCPs and 3.5 mm LCPs. The 3.5 mm plates provided 80% of the axial stiffness and 75% of the torsional stiffness of the 4.5 mm plates. The 3.5 mm plated bones failed at 79% of the mean failure load of the 4.5 mm plated bones. The 3.5 mm plated bones failed due to incidental torsion during axial loading; the 4.5 mm plated bones failed as a result of gap closure. Interpretation Our results followed expectations due to differences in plate dimensions. There were no apparent differences between constructs following cyclic loading. Our model includes a fracture gap, which requires the plate to carry the entire load. This does not simulate the actual clinical scenario wherein healing would tend to improve construct performance. While the constructs performed differently, both appear to support loads that are anticipated in the clinical setting.

Publisher

Charter Services New York d/b/a Journal of Orthopaedic Experience and Innovation

Reference44 articles.

1. Compression plating versus intramedullary fixation of humeral shaft fractures;Paul R. Gregory;Journal of the American Academy of Orthopaedic Surgeons,1997

2. Surgical versus non-surgical interventions for treating humeral shaft fractures in adults;Maurits W. Gosler;Cochrane Database of Systematic Reviews,2012

3. The impact of residual angulation on patient reported functional outcome scores after non-operative treatment for humeral shaft fractures;Edward Shields;Injury,2016

4. Humeral shaft fractures;Gary F. Updegrove;Journal of Shoulder and Elbow Surgery,2018

5. Nonoperative treatment of humeral shaft fractures revisited;Erden Ali;Journal of Shoulder and Elbow Surgery,2015

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3