REtrospective Multicenter INdian Study of Derivo Embolization Device (REMIND): Periprocedural Safety

Author:

Mahajan Niranjan PrakashORCID,Mushtaq MudasirORCID,Bhatti AmitORCID,Purkayastha SukalyanORCID,Dange NitinORCID,Cherian MathewORCID,Gupta VipulORCID,Huded VikramORCID

Abstract

Purpose: The treatment of aneurysms with characteristics such as complex morphology, fusiform, blister-like, wide neck, or large size has been revolutionized with the introduction of flow diverters. Though flow diverters have several advantages over coiling, they also have certain important disadvantages such as the lack of immediate protection against rupture, the risk of ischemic stroke, the need for antiplatelet therapy, and long latency for complete effect. The Derivo Embolization Device (DED) is a second-generation self-expanding device that is claimed to be less thrombogenic than conventional devices. We retrospectively evaluated the periprocedural safety and risks associated with the DED across 5 centers in India.Materials and Methods: This is a multicentric, retrospective, observational study of DED, conducted at 5 high volume endovascular therapy centers in India from May 2018 to June 2020. Periprocedural demographic, clinical, and angiographic data were collected from a retrospective review of patient charts.Results: A total of 96 patients, including 56 (58.3%) females, aged between 16–80 years (60±12.7 years) harboring 106 aneurysms were studied. Seven (7.3%) were noted to harbor multiple aneurysms: 6 had 3 aneurysms each, while 1 patient had 5 aneurysms. The following aneurysm characteristics were noted: average size, 9.8±8.2 mm; average neck size, 6.9±8.5 mm; wide-necked (>4 mm), 63 (59.4%); giant (>25 mm), 8 (7.5%); and anterior circulation location, 98 (92.5%). Eighteen (17%) of these were ruptured. Additional balloon angioplasty was performed in 5 (5.2%) patients. Intraprocedural problems were encountered in 3 (3.1%), of which only 1 had clinical implications, the device fish-mouthing with stent thrombosis resulting in a malignant middle cerebral artery territory infarction. The modified Rankin scale at 3 months was worse in 1 patient.Conclusion: DED is a newer generation flow diverter stent with a low periprocedural complication rate.

Publisher

Korean Society of Interventional Neuroradiology

Subject

General Earth and Planetary Sciences,General Environmental Science

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3