Evaluating a Wearable Solution for Measuring Lower Extremity Asymmetry during Landing

Author:

Räisänen Anu M.12,Benson Lauren C.23,Whittaker Jackie L.2456,Emery Carolyn A.2678

Affiliation:

1. Department of Physical Therapy Education, College of Health Sciences – Northwest, Western University of Health Sciences, Lebanon, Oregon, United States

2. Sport Injury Prevention Research Centre, University of Calgary, Calgary, Alberta, Canada

3. Tonal Strength Institute, Tonal, San Francisco, California, , United States

4. Department of Physical Therapy, Faculty of Medicine, University of British Columbia, Vancouver, British Columbia, Canada

5. Arthritis Research Canada, Richmond, British Columbia, Canada

6. McCaig Bone and Joint Institute, Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada

7. Alberta Children’s Hospital Research Institute, University of Calgary, Calgary, Canada

8. Department of Pediatrics and Community Health Sciences, Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada

Abstract

Purpose: Force plates can be used to monitor landing asymmetries during rehabilitation, but they are not widely available. Accelerometer-based wearable technology may be a more feasible solution. The purpose of this article was to determine the agreement between impact accelerations measured with force plates and accelerometer-derived measures of (1) centre of mass (COM) acceleration and (2) tibial acceleration asymmetries during bilateral landings. Method: Participants completed three countermovement jumps (CMJ) and three squat jumps (SJ) on dual force plates with triaxial accelerometers attached to each tibia and lower back, near the COM. Bland and Altman 95% limits of agreement (95% LOA) were calculated. Results: 19 adults ( n = 11; 58% women, n = 8; 42% men) participated in the study. The mean differences between impact and COM accelerations were 0.24g (95% LOA; –1.34 g to 1.82 g) and 0.38 g (95% LOA; −1.15 g to 1.91 g) for the CMJ and SJ, respectively. The mean differences between the impact and tibial acceleration-based lower limb asymmetries in the CMJ and SJ were −6% (95% LOA; −32% to 19%) and 0% (95% LOA; −45% to 45%), respectively. Conclusions: Our findings show acceptable agreement between impact acceleration and accelerometer-based COM acceleration and lack of agreement between impact accelerations and accelerometer-based tibial acceleration asymmetries. COM acceleration could be used to quantify landing impacts during rehabilitation, but we do not consider the accelerometer-based asymmetry measures to be a suitable alternative for force plate-based measures. Future work should focus on determining normative values for lower extremity asymmetries during landing tasks.

Publisher

University of Toronto Press Inc. (UTPress)

Subject

Physical Therapy, Sports Therapy and Rehabilitation

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献