Contrast‐enhanced ultrasound repeatability for the measurement of skeletal muscle microvascular blood flow

Author:

Jones Eleanor J.1,Atherton Philip J.1,Piasecki Mathew1ORCID,Phillips Bethan E.1

Affiliation:

1. Centre of Metabolism, Ageing and Physiology, MRC‐Versus Arthritis Centre for Musculoskeletal Ageing Research and National Institute for Health Research (NIHR) Nottingham Biomedical Research Centre University of Nottingham Derby UK

Abstract

New Findings What is the central question of this study? Contrast‐enhanced ultrasound (CEUS) can be used to directly assess skeletal muscle perfusion but its day‐to‐day repeatability over time has not yet been validated: is CEUS a repeatable method for the measurement of skeletal muscle microvascular blood flow (MBF) at rest and in response to exercise, across independent assessment sessions? What is the main finding and its importance? A strong agreement between CEUS MBF measures across sessions suggests it is a repeatable method for assessing skeletal muscle perfusion over time. This validation provides confidence for incorporating these measures into longitudinal studies such as a chronic intervention or disease progression to gain further knowledge of skeletal muscle microvascular function. AbstractContrast‐enhanced ultrasound (CEUS) can be used to directly assess skeletal muscle perfusion. However, its repeatability over time has not yet been validated and therefore its use in longitudinal measures (i.e., exploring the impact of a chronic intervention or disease progression) is limited. This study aimed to determine the repeatability of CEUS for the measurement of skeletal muscle microvascular blood flow (MBF) at baseline and in response to exercise, across independent assessment sessions. Ten healthy volunteers (five female; 30 ± 6 years) had CEUS of the right vastus lateralis recorded in two separate sessions, 14 days apart. Measurements were taken at baseline, during an isometric leg extension and during recovery. Acoustic intensity data from a region of interest were plotted as a replenishment curve to obtain blood volume (A) and flow velocity (β) values from a one‐phase association non‐linear regression of mean tissue echogenicity. Linear regression and Bland–Altman analyses of A and β values were performed, with significance assumed as P < 0.05. Strong positive correlations were observed across sessions for all A and β values (both P < 0.0001). Bland–Altman analysis showed a bias (SD) of −0.013 ± 1.24 for A and −0.014 ± 0.31 for β. A bias of 0.201 ± 0.770 at baseline, 0.527 ± 1.29 during contraction and −0.203 ± 1.29 at recovery was observed for A, and −0.0328 ± 0.0853 (baseline), −0.0446 ± 0.206 (contraction) and 0.0382 ± 0.233 (recovery) for β. A strong agreement between CEUS MBF measures across independent sessions suggests it to be a repeatable method for assessing skeletal muscle perfusion over time, and therefore facilitates wider use in longitudinal studies.

Funder

Biotechnology and Biological Sciences Research Council

Publisher

Wiley

Subject

Physiology,Physiology (medical),Nutrition and Dietetics,Physiology,Physiology (medical),Nutrition and Dietetics

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3