Abstract
Purpose: To compare the clinical outcomes of intrascleral fixation of the three-piece intraocular lenses (IOLs) 2.5 mm posterior to the limbus with ciliary sulcus implantation and transscleral fixation 2.5 mm posterior to the limbus.Methods: Sixty-five eyes of 65 patients who underwent ciliary sulcus implantation or transscleral or intrascleral fixation of the AMO Sensar AR40e IOL were retrospectively reviewed. The postoperative refractive prediction error, back-calculated effective lens position (ELP), corrected distance visual acuity (CDVA), and postoperative residual cylinder were compared.Results: There were significant differences in the median (interquartile range) postoperative refractive prediction error (diopters [D]) among the three groups (<i>p</i> < 0.001): for ciliary sulcus implantation (33 eyes), −0.89 D (−1.21 to −0.56 D); for transscleral fixation (10 eyes), −0.40 D (−0.78 to −0.22 D); and for intrascleral fixation (22 eyes), 0.01 D (−0.28 to 0.34 D). Significant differences (<i>p</i> < 0.001) were observed in the median back-calculated ELP: for ciliary sulcus implantation, 4.35 mm (3.95 to 4.55 mm); for transscleral fixation, 4.51 mm (4.34 to 4.76 mm); and for intrascleral fixation, 4.90 mm (4.56 to 5.35 mm). There were no differences in the median postoperative CDVA (0, 0.10, and 0 logarithm of the minimum angle of resolution, respectively; <i>p</i> = 0.083) and the residual cylinder (−0.75, −1.50, and −0.63 D, respectively; <i>p</i> = 0.074) among three groups.Conclusions: Intrascleral fixation showed no myopic shift and the most posterior lens position, while ciliary sulcus implantation induced the greatest myopic shift and the most anterior lens position. However, there was no significant difference in the postoperative CDVA or astigmatism among the eyes with different IOL insertion methods, demonstrating good IOL stability and vision outcomes.
Funder
Seoul National University Bundang Hospital
College of Medicine, Korea University
Korea Institute of Science and Technology
Korea University
Ministry of Science and ICT
Ministry of Trade, Industry and Energy
Ministry of Health and Welfare
Ministry of Food and Drug Safety
Korea Environmental Industry and Technology Insitute
Ministry of Environment
National Research Foundation of Korea
Ministry of SMEs and Startups
Publisher
Korean Ophthalmological Society
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献