Comparison of Each Eye According to the Order of Noninvasive Keratographic Tear Film Evaluation

Author:

Shin Haeeun,Jung Soyeon,Jung Ji Won

Abstract

Purpose: To investigate the effect of order of examination on the results of noninvasive keratograph tear film evaluation using Keratograph5M in dry eye patients.Methods: One hundred and four patients with dry eye symptoms were analyzed retrospectively. All patients underwent bilateral noninvasive tear film evaluation using measurements of tear meniscus height (TMH) and noninvasive keratograph break-up time (NIKBUT) obtained using Keratograph5M. Measurements were performed sequentially in the order of right TMH, left TMH, right NIKBUT, and left NIKBUT.Results: There was no statistically significant difference in TMH values between the right and left eyes (0.24 ± 0.08 and 0.23 ± 0.08 mm, respectively). Mean NIKBUT-first (time at first tear film break-up) and mean NIKBUT-average (the mean of all tear film break-up time over the entire cornea) were 6.17 ± 3.28 and 10.00 ± 3.97 seconds, respectively, for right, and 7.43 ± 3.86 and 11.57 ± 4.34 seconds, respectively, for left eyes. In addition, mean NIKBUT-first between right and left eyes, and mean NIKBUT-average between them were statistically significant (p = 0.013 and p = 0.007, respectively). Mean NIKBUT and mean TMH differences were not significantly influenced by right or left eyes, age, or sex (all p > 0.050). Spearman correlation analyses of TMH, NIKBUT-first, and NIKBUT-average results showed moderate positive correlations between right and left eyes (r = 0.470, r = 0.322, and r = 0.576, respectively; p < 0.001).Conclusions: TMH evaluation was not affected by test order; however, NIKBUT measurement was affected by test order, because of reflex tearing due to forced eye opening during the examination. Therefore, TMH should be evaluated before NIKBUT, and sufficient time interval and caution should be needed between NIKBUT measurements on both eyes.

Funder

National Research Foundation of Korea

Ministry of Science and ICT

Inha University Hospital

Publisher

Korean Ophthalmological Society

Subject

Ophthalmology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3