Combined Performance of Fecal Immunochemical Tests and a Genetic Risk Score for Advanced Neoplasia Detection

Author:

Niedermaier Tobias1ORCID,Guo Feng12ORCID,Weigl Korbinian1ORCID,Hoffmeister Michael1ORCID,Brenner Hermann134ORCID

Affiliation:

1. 1Division of Clinical Epidemiology and Aging Research, German Cancer Research Center (DKFZ), Heidelberg, Germany.

2. 2Medical Faculty Heidelberg, University of Heidelberg, Heidelberg, Germany.

3. 3Division of Preventive Oncology, German Cancer Research Center (DKFZ) and National Center for Tumor Diseases (NCT), Heidelberg, Germany.

4. 4German Cancer Consortium (DKTK), German Cancer Research Center (DKFZ), Heidelberg, Germany.

Abstract

Abstract Fecal immunochemical tests (FITs) are increasingly used as noninvasive screening tests in colorectal cancer–screening programs. Polygenic risk scores (PRS) are increasingly propagated for risk stratification in colorectal cancer screening. We aimed to assess the potential of combining FIT results and PRS to enhance diagnostic accuracy of detecting advanced neoplasia (AN) compared with using FIT results alone. Of 10,362 participants of screening colonoscopy in Southern Germany who conducted either one of two quantitative FITs, genotyping was done in all participants with AN (colorectal cancer or advanced adenoma) and a random subset of controls. Among 5,306 individuals, a PRS was calculated on the basis of the number of risk alleles in 140 SNPs. Partial areas under the receiver operating characteristics (ROC) curves (pAUCs) were computed for FIT and PRS alone and combined, focusing on a specificity range of 100%–80%. Both FITs showed similar performance characteristics with pAUCs of 0.661 (95% confidence interval (CI), 0.625–0.698; Ridascreen Hemoglobin) and 0.682 (95% CI, 0.661–0.701; FOB Gold) for AN detection. PRS alone reached a pAUC of 0.524 (95% CI, 0.499–0.550) and 0.530 (95% CI, 0.516–0.545), respectively, and its addition to FIT did not improve pAUCs (0.659; 95% CI, 0.622–0.697) and 0.667 (95% CI, 0.650–0.687), respectively. This finding was confirmed by investigating sensitivities at fixed specificities at 85%, 90%, and 95%. Partial AUCs also did not improve when adding the weighted PRS to FIT instead of the unweighted PRS. In summary, the combination with PRS did not improve diagnostic accuracy of FIT-based screening in a large asymptomatic colorectal cancer screening population from South-Western Germany. Prevention Relevance: In our study, combining polygenic risk score with fecal immunochemical test (FIT) did not improve diagnostic accuracy for advanced colorectal neoplasia detection compared with FIT alone. So far, such a combination cannot be recommended because it would come at extra costs and effort despite no relevant gain in neoplasia detection.

Funder

German Research Council

Federal Ministry of Education and Research

German Cancer Aid

Publisher

American Association for Cancer Research (AACR)

Subject

Cancer Research,Oncology

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3