A comparison of root canal preparations using stainless steel, Ni-Ti hand, and Ni-Ti engine-driven endodontic instruments – an in vitro study

Author:

Parvathaneni Krishna Prasad,Goel Beena Rani,Parvathaneni Bharani Devi

Abstract

The main advantage of nickel titanium instruments is that they permit canal preparation with less transportation and ledging. Hand used Ni-Ti and rotary Ni-Ti instruments have a wider range of elastic deformation and greater flexibility. The aim of the present study was to evaluate and compare the preparation time, loss of working length, apical transportation, instrument deformation and fracture with stainless steel, Ni-Ti hand and Ni-Ti rotary endodontic instruments. Fifty freshly extracted human mandibular molars with curved roots were collected and stored in 10% formalin. The samples were divided into 3 groups of 15 each. The access opening was made for each tooth and the biomechanical preparation was carried out using crown down pressureless technique in all the groups. Group I was instrumented with stainless steel files, group II with hand Ni-Ti and group III with Ni-Ti rotary files. The preparation time to enlarge each canal was recorded in minutes and seconds, which included only active instrumentation. Following preparation, the final length of each canal was subtracted from the original length to give the loss of working length. SEM photographs of the deformed and fractured instruments were taken. The apical transportation was measured using computer software (Microdraw 4.1). The readings were noted and statistically analyzed.The results of this in vitro study showed that the mean preparation time was less with Ni- Ti rotary (1.85 min) when compared to hand Ni-Ti (6.33) and stainless steel files (6.73), which was statistically significant. The loss of working length was more for stainless steel group which was statistically significant (P<0.05) when compared with the other 2 groups.One instrument in stainless steel and one in Ni-Ti rotary files were fractured. Only one instrument in stainless steel file deformed permanently. Apical transportation was found to be greater in stainless steel group than other groups (P<0.01) which was statistically significant. Considering the parameters in this study, Ni-Ti rotary files proved to perform better than the other two groups. Key words: Canal preparation; crown-down pressure less technique; double exposure radiographic technique. DOI: 10.3329/bjms.v9i4.6689Bangladesh Journal of Medical Science Vol.09 No.4 July 2010 pp.223-230

Publisher

Bangladesh Journals Online (JOL)

Subject

General Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3