Tracheostomy Tube Exchange Failure Under General Anesthesia: A Case Report and Retrospective Analysis

Author:

Kojima Yuki1,Sendo Ryozo23,Hirabayashi Kazuya1

Affiliation:

1. 1 Department of Anesthesiology, Asahi General Hospital, Chiba, Japan

2. 2 Department of Anesthesiology, Imakiire General Hospital, Kagoshima, Japan

3. 3 Department of Dentistry and Oral Surgery, Imakiire General Hospital, Kagoshima, Japan

Abstract

A 54-year-old man with squamous cell carcinoma of the tongue underwent bilateral cervical lymph node dissection, total tongue resection, forearm flap reconstruction, and tracheostomy. The plan was to replace the oral endotracheal tube (ETT) with a cuffed tracheostomy tube at the end of the surgical case while the patient was still under general anesthesia. No major complications were expected as the tracheal foramen was visible once surgical access was obtained. However, removal of the ETT and subsequent placement of the tracheostomy tube failed twice. Successful ventilation was not observed via capnography, and the patient’s peripheral oxygen saturation (SpO2) dropped to 70%. The anesthesiologist concluded that securing the airway through the tracheostomy would be difficult. The patient was immediately reintubated orally at which time his SpO2 was 38%, and he was successfully resuscitated and recovered without any sequelae. This rare situation was one we had not encountered previously, so we retrospectively analyzed all tracheostomy cases performed by our department from the past 3 years. Data from 54 patients who underwent tracheostomy tube exchange after tracheostomy were aggregated from their medical records and compared with our patient. Excluding the conditions during surgery, we surmised that tracheal depth, S/H ratio, and body weight were identified as potentially significant risk factors for failed tracheal tube placement or exchange.

Publisher

American Dental Society of Anesthesiology (ADSA)

Subject

Anesthesiology and Pain Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3