Clinical efficiency and stability of surface-modified implants: acid modification versus photoactivation

Author:

Terekhov Serhii S.1,Proshchenko Andriy M.1,Proshchenko Nina S.1,Shorikova Dina V.2

Affiliation:

1. INSTITUTE OF POSTGRADUATE EDUCATION OF THE O.O. BOGOMOLETS NATIONAL MEDICAL UNIVERSITY, KYIV, UKRAINE

2. BUKOVINIAN STATE MEDICAL UNIVERSITY, CHERNIVTSI, UKRAINE

Abstract

Aim: To study the stability of surface-modified dental implants, with the usage of sandblasting/acid modification vs. photoactivation. Materials and Methods: In the observation were included 164 patients with dental defects. All patients had digital impressions taken by scanning the oral cavity with an intraoral scanner 3Shape TRIOSR. Group A (80 subjects) included implants whose surface was modified with a combination of sandblasting and acid. Group B (84 subjects) - implants after modification with photoactivation. The implant stability quotient was recorded using an Osstell MentorTM device. Results: The reliable effectiveness of the photoactivation method in complex treatment of the surface of dental implants in improving the stability of fixed dentures in the short and long-term periods of observation was proven. When assessing immediate clinical outcomes, there was no significant difference in the frequency of hyperemia, algesia, hyperthermia, soft tissue edema, regional lymphadenitis, depending on the classical method of treating the implant surface and the complex method with photoactivation. Of the long-term clinical outcomes with classical surface treatment, the absolute risk of implant failure was 1.2%, relative risk – 0,99 [CI%0,96-1,0]. The average value of the implant stability coefficient (ISQ) and the data of the Periotest study at the time of surgery probably did not differ in the observation groups, after 3 months, a higher index was proven in the treatment of the surface by the method of photoactivation and greater stability of the mandibular implants. At the time of implantation, there were no statistically significant differences in implant fixation between the groups, however, during prospective observation in group A, secondary stability indicators based on periotestometry results were significantly lower. Conclusions: It was proved the reliable effectiveness of the photoactivation-method for surface modification in the short and long-term periods of observation for improving the results of orthodontically treatment.

Publisher

ALUNA

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3