Navigated percutaneous screw fixation of the pelvis with O-arm 2: two years’ experience

Author:

Ciolli Gianluca1ORCID,Caviglia Daniele1,Vitiello Carla2,Lucchesi Salvatore1,Pinelli Corrado1,De Mauro Domenico1,Smakaj Amarildo1,Rovere Giuseppe1,Meccariello Luigi3,Camarda Lawrence4,Maccauro Giulio1,Liuzza Francesco1

Affiliation:

1. A. Gemelli University Hospital Foundation IRCCS, Catholic University

2. Ospedali Riuniti - Area Vesuviana - ASL Napoli 3 sud

3. AORN San Pio

4. University of Palermo

Abstract

<p><strong>Aim <br /></strong>To evaluate the case series of the patients operated with percutaneous fixation by the navigation system based on 3D fluoroscopic images, to assess the precision of a surgical implant and functional outcome of patients.<br /><strong>Methods <br /></strong>A retrospective study of pelvic ring fractures in a 2-year period included those treated with the use of the O-Arm 2 in combination with the Stealth Station 8. Pelvic fractures were classified according to the Tile and the Young-Burgess classification. All patients were examined before surgery, with X-rays and CT scans, and three days after surgery with additional CT scan. The positioning of the screws was evaluated according to the Smith score, the outcome with the SF-36.<br /><strong>Results</strong> <br />Among 24 patients 18 were with B and six with C type fracture according to Tile, while eight were with APC, 10 LC, and<br />six with VS type according to Young-Burgess classification. All patients were treated in the supine position, except two. A total of 41 iliosacral or transsacral screws and five anterior pelvic ring screws were implanted. The medium surgical time per screw was 41 minutes. There was a perfect correspondence of screw scores value from post-operative CT and intraoperative fluoroscopy. The mean screw score value was 0.92. There were no cases of poor positioning. The median follow-up was 17.5 months. The patients were satisfied with their health condition on SF-36.<br /><strong>Conclusion </strong><br />The use of the O-arm guarantees great precision in the positioning of the screws and reduced surgical times with excellent<br />clinical results in patients.</p>

Publisher

Medical Association of Zenica-Doboj

Reference36 articles.

1. A nationwide analysis of pelvic ring fractures: incidence and trends in treatment, length of stay, and mortality;LBullerL;Geriatr Orthop Surg Rehabil,2016

2. Prevalence of pelvic fractures, associated injuries and mortality: The United Kingdom perspective;PGiannoudisP;J Trauma,2007

3. Epidemiology of pelvic ring fractures and injuries;GjcPereiraGjc;Rev Bras Ortop,2017

4. Is there a role for percutaneous pelvic and acetabular reconstruction?;PRommensP;Injury,2007

5. Percutaneous management of unstable pelvic ring disruptions;DBareiD;Injury,2001

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3