Locking plate fixation combined with iliac crest bone autologous graft for proximal humerus comminuted fracture

Author:

Zhu Lian,Liu Yueju,Yang Zongyou,Li Han,Wang Juan,Zhao Changping,Chen Xiao,Zhang Yingze

Abstract

Background Although the use of an intramedullary fibular allograft together with locking plate fixation can provide additional medial support and prevent varus malalignment in displaced proximal humeral fractures with promising results, the fibular autograft donor site often sustains significant trauma and cannot restore the articular surface of comminuted fractures. The aim of this study was to evaluate the clinical and radiographic outcomes of a locking plate and crest bone autologous graft for treating proximal humerus comminuted fractures. Methods We assessed the functional outcomes and complication rates in 40 patients with proximal humerus comminuted fractures. Eighteen patients were treated with a locking plate and an autologous crest bone graft (experimental group), and 22 were treated with only the locking plate and no bone graft (control group). Postoperative assessments included radiographic imaging, range of motion analysis, pain level based on the visual analogue scale (VAS), and the SF-36 (Short Form (36) Health Survey), as well as whether patients could return to their previous occupation. Results All fractures healed both clinically and radiologically in the experimental group. There was no more than 2 mm collapse of the humeral head, and no osteonecrosis or screw penetration of the articular surface. In contrast, two patients had a nonunion in the control group, and they eventually accepted total shoulder replacements. The average time from surgery to radiographic union was significantly shorter in the experimental group ((4.66±1.63) months) compared with the control group ((5.98±1.57) months) (P <0.05). For the experimental versus controls groups, the mean shoulder active flexion (148.00±18.59 vs. 121.73±17.20) degrees, extension (49.00±2.22 vs. 42.06±2.06) degrees, internal rotation (45.00±5.61 vs. 35.00±3.55) degrees, external rotation (64.00±9.17 vs. 52.14±5.73) degrees, and abduction (138.00±28.78 vs. 105.95±15.66) degrees were all significantly higher (all P <0.001). The median SF-36 in the experimental group ((88.00±5.71) points) was significantly higher than that of the control group ((69.45±9.45) points; P <0.001). The median VAS pain level (mean rank, 10.50) in the experimental group was lower than that (mean rank, 47.19) of the control group (P <0.001). All but one patient (17 of 18, 94.4%) in the experimental group returned to their previous activities or occupations, and that one patient changed to a different occupation because of slight restrictions to activities. On the other hand, four patients could not return to their previous activities or occupations in the control group. Conclusion Locking plate fixation combined with an iliac crest bone graft is an effective technique for treating proximal humerus comminuted fractures.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Reference28 articles.

1. Operative treatment of nonunion of surgical neck fractures of the humerus.;Nayak;Clin Orthop Relat Res,1995

2. Orthopaedics and traumatology in China: current status and future.;Zhang;Chin Med J,2012

3. Osteoporosis and the orthopaedic surgeon.;Leung;Chin Med J,2013

4. Operative treatment of severe proximal humeral fractures.;Paavolainen;Acta Orthop Scand,1983

5. Anterolateral acromial approach in locking plate fixation of proximal humerus fractures in elderly patients.;Cai;Acta Orthop Belg,2013

Cited by 26 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3