Investigation on the optical scan condition for imaging of multi-slice spiral CT liver perfusion in rats

Author:

BAI Rong-jie,WANG Jin-e,JIANG Hui-jie,HAO Xue-jia,DONG Xu-peng,HUANG Ya-hua,WEI Lai

Abstract

Background Multi-slice CT liver perfusion has been widely used in experimental studies of hemodynamic changes in liver lesions, and is usually performed as an adjunct to a conventional CT examination because of its high temporal and spatial resolution, simple protocol, good reproducibility, and ability to measure hemodynamic changes of liver tissues at the capillary level. Experimental rat models, especially those of induced liver cancer, are often used in studies of hemodynamic changes in liver cancer. Carcinogenesis in rats has a similar pathological progression and characteristics resembling those in human liver cancer; as a result, rat models are often used as ideal animal models in the study of human liver cancer. However, liver perfusion imaging in rats is difficult to perform, because rats' livers are so small that different concentrations, flow rates, and dose of contrast agents during the CT perfusion scanning can influence the quality of liver perfusion images in rats. The purpose of this study, therefore, was to investigate the optimal scan protocol for the imaging of hepatic perfusion using a deconvolution mathematical method in rats by comparing the results of rats in different injection conditions of the contrast agent, including concentration, rate and time. Methods Plain CT scan conditions in eighty 2-month-old male Wistar rats were 5.0 mm slice thickness, 5.0 mm interval, 1.0 pitch, 120 kV tube voltage, 60 mA tube current, 512×512 matrix, and FOV 9.6 cm. Perfusion scanning was carried out with different concentrations of diatrizoate (19%, 38%, 57%, and 76%), different injection rates (0.3 and 0.5 ml/s), and different injection times (1, 2-3, 4-5, and 6 seconds). The above conditions were randomly matched and adjusted to determine the best perfusion scan protocol. Three-phase contrast-enhanced scanning was performed after CT perfusion. Histological examination of the liver tissues with hematoxylin and eosin stains was done after CT scanning. Results When the concentration of the contrast agent was 19% or 38%, no pseudo-color map was created. The viscosity increased when the concentration of the contrast agent was 76%; so it is difficult to inject the contrast agent at such a high concentration. Also no pseudo-color map was generated when the injection time was short (1, 2-3, and 4-5 seconds) or the injection rate was low (0.3 ml/s). The best perfusion images and perfusion parameters were obtained during 50 seconds scanning. Each rat was given an injection of 57% diatrizoate at 0.5 ml/s via the tail vein using a high-pressure syringe for 6 seconds. The perfusion parameters included hepatic blood flow (HBF), hepatic blood volume (HBV), mean transit time (MTT) of the contrast agent, capillary permeability-surface area product (PS), hepatic arterial index (HAI), hepatic artery perfusion (HAP), and hepatic portal perfusion (HPP). All these parameters reflected the perfusion status of liver parenchyma in normal rats. Three phases of enhancement were modified according to the time-density curves (TDCs) of the perfusion imaging: hepatic arterial phase (7 seconds), hepatic portal venous phase (15 seconds), and a delayed phase (23-31 seconds). On examination by microscopy, the liver tissues were pathologically normal. Conclusions The appropriate protocol with multi-slice spiral CT liver perfusion reflected normal liver hemodynamics in rats. This study laid a solid foundation for further investigation of the physiological characteristics of liver cancer in a rat model, and was an important supplement to and reference for conventional contrast-enhanced CT scans.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3