Abstract

Background Adjacent segment degeneration could seriously affect the long-term prognosis of lumbar fusion. Dynamic fixation such as the interspinous fixation, which is characterized by retaining the motion function of the spinal segment, has obtained satisfactory short-term effects in the clinical setting. But there are few reports about the biomechanical experiments on whether dynamic fixation could prevent adjacent segment degeneration. Methods The surgical segments of all 23 patients were L4/5. Thirteen patients with disc herniation of L4/5 underwent Wallis implantation surgery, and 10 patients with spinal stenosis of L4/5 underwent posterior lumbar interbody fusion (PLIF). L3-S1 segmental stiffness and displacement were measured by a spine stiffness gauge (SSG) device during surgery when the vertebral plate was exposed or during spinal decompression or internal fixation. Five fresh, frozen cadavers were used in the self control experiment, which was carried out in four steps: exposure of the vertebral plate, decompression of the spinal canal, implantation of a Wallis fixing device, and PLIF of L4/5 after removing the Wallis fixing device. Then, L3-S1 segment stiffness was measured by an SSG device. Results The experiments showed that the average stiffness of the L4/5 segment was (37.1±8.9) N/mm after exposure of the vertebral plate, while after spinal decompression, the average stiffness fell to (26.2±7.1) N/mm, decreasing by 25.8% (P <0.05). For the adjacent segments L3/4 and L5/S1, their stiffness showed no significant difference between the L4/5 segment decompression and the exposure of the vertebral plate (P >0.05). After Wallis implantation of L4/5, the stiffness of the cephalic adjacent segment L3/4 was (45.8±10.7) N/mm, which was 20.5% more than that after the exposure of the vertebral plate (P <0.05); after L4/5 PLIF surgery, the stiffness of L3/4 was (35.3±10.7) N/mm and was decreased by 12.4% more than that after the exposure of the vertebral plate (P <0.05). The stiffness of the cephalic adjacent segment L3/4 after fixation in the Wallis group was significantly higher than that of the PLIF group (P <0.05). Cadaver experiments showed that the stiffness of the cephalic adjacent segment in the Wallis group was significantly higher than that of the PLIF group after L4/5 segment fixation (P <0.05); the stiffness of the L5/S1 segment showed no significant difference between PLIF surgery and Wallis implantation (P >0.05). Conclusions After interspinous (Wallis) fixation, the stiffness of the cephalic adjacent segment increased. After PLIF with pedicle screw fixation, the stiffness of the cephalic adjacent segment decreased. An interspinous fixation system (Wallis) has a protective effect for cephalic adjacent segments for the immediate post-operative state.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

General Medicine

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

全球学者库

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"全球学者库"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前全球学者库共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2023 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3