Septic shock in obstetrics: the role of efferent techniques for endotoxin removal in Gram-negative sepsis

Author:

Bayalieva A. Zh.1ORCID,Davydova V. R.1ORCID

Affiliation:

1. Kazan State Medical University, Health Ministry of Russian Federation; Republican Clinical Hospital, Ministry of Health of the Republic of Tatarstan

Abstract

Aim: to assess the sorption capacity of various devices for endotoxin removal modelled in in vitro patient with septic shock experiment.Materials and Methods. Endotoxin adsorption was evaluated in vitro by using circulating endotoxin solution in bovine serum in a closed circuit. The following columns were chosen for the experiment: Toraymyxin PMX-20R (РМ Х), Alteco® LPS Adsorber, Efferon LPS, Toray Filtryzer BK-2.1U. Lipopolysaccharide (LPS) doses corresponding to severity of the septic process were sequentially added to a column pre-washed with physiological solution. The first LPS dose of 12.5 µg was added to a flask containing 1500 ml (1.5 L) of fetal bovine serum, a second LPS dose of 37.5 µg was added at 120 minute; the serum samples were collected before the onset of experiment, as well as 30, 60, 120 (before the second dose), 120 (after the second dose), 150 and 240 minutes after the start of circulation. LPS measurement was carried out by mixing the prepared serum sample with LAL reagent at 1:1 ratio in a measuring tube.Results. All columns can reduce endotoxin levels below the 12.5 µg and even 50 µg levels, although none of devices were able to reduce the LPS level from “supercritical” 50 µg to “critical” 12.5 µg. However, at the same time, the capacity of the Toraymyxin PMX-20R column turned out to be 5-13 times greater than that of other products. This result suggests that while removing endotoxin under similar conditions, the Toraymyx in PMX-20R column will have a much higher reserve of sorption capacity and, therefore, greater opportunities for lowering a risk of septic shock progression.Conclusion. The study we presented provides insights into whether sorption capacity of the tested cartridges is sufficient to remove endotoxin at initial (12.5 µg) load that corresponds to the onset of systemic inflammatory response syndrome in a typical patient. Additionally, it elucidates to what extent a cartridge can reduce the endotoxin load in severe septic shock with a total LPS load of up to 50 µg.

Publisher

IRBIS

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3