A few case reports and case series have documented the outcomes in patients with tricuspid bioprosthetic valvular degeneration who underwent transcatheter implantation of the Medtronic Melody and the Edwards Sapien XT and Sapien 3 valves. In this report, we describe the case of a 49-year-old woman with severe bioprosthetic tricuspid valvular stenosis and multiple comorbidities who underwent transcatheter tricuspid valve replacement with a Sapien 3 valve.