Benefit of Contact Force–Guided Catheter Ablation for Treating Premature Ventricular Contractions

Author:

Zhao Ziming,Liu Xiaowei,Gao Lianjun,Xi Yutao,Chen Qi,Chang Dong,Xiao Xianjie,Cheng Jie,Yang Yanzong,Xia Yunlong,Yin Xiaomeng

Abstract

We evaluated whether an irrigated contact force–sensing catheter would improve the safety and effectiveness of radiofrequency ablation of premature ventricular contractions originating from the right ventricular outflow tract. We retrospectively reviewed the charts of patients with symptomatic premature ventricular contractions who underwent ablation with a contact force–sensing catheter (56 patients, SmartTouch) or conventional catheter (59 patients, ThermoCool) at our hospital from August 2013 through December 2015. During a mean follow-up of 16 ± 5 months, 3 patients in the conventional group had recurrences, compared with none in the contact force group. Complications occurred only in the conventional group (one steam pop; 2 ablations suspended because of significantly increasing impedance). In the contact force group, the median contact force during ablation was 10 g (interquartile range, 7–14 g). Times for overall procedure (36.9 ± 5 min), fluoroscopy (86.3 ± 22.7 s), and ablation (60.3 ± 21.4 s) were significantly shorter in the contact force group than in the conventional group (46.2 ± 6.2 min, 107.7 ± 30 s, and 88.7 ± 32.3 s, respectively; P <0.001). In the contact force group, cases with a force-time integral <560 gram-seconds (g-s) had significantly longer procedure and fluoroscopy times (both P <0.001) than did those with a force-time integral ≥560 g-s. These findings suggest that ablation of premature ventricular contractions originating from the right ventricular outflow tract with an irrigated contact force–sensing catheter instead of a conventional catheter shortens overall procedure, fluoroscopy, and ablation times without increasing risk of recurrence or complications.

Publisher

Texas Heart Institute Journal

Subject

Cardiology and Cardiovascular Medicine

Reference22 articles.

1. Determinants of lesion size during radiofrequency catheter ablation: the role of electrode-tissue contact pressure and duration of energy delivery;Haines;J Cardiovasc Electrophysiol,1991

2. Recent advances in lesion formation for catheter ablation of atrial fibrillation;Barnett;Circ Arrhythm Electrophysiol,2016

3. Novel contact force sensor incorporated in irrigated radiofrequency ablation catheter predicts lesion size and incidence of steam pop and thrombus;Yokoyama;Circ Arrhythm Electrophysiol,2008

4. Area under the real-time contact force curve (force-time integral) predicts radiofrequency lesion size in an in vitro contractile model;Shah;J Cardiovasc Electrophysiol,2010

5. Importance of catheter contact force during irrigated radiofrequency ablation: evaluation in a porcine ex vivo model using a force-sensing catheter;Thiagalingam;J Cardiovasc Electrophysiol,2010

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3