Author:
Baldwin Andrew C.W.,Gemmato Courtney J.,Sandoval Elena,Cohn William E.,Morgan Jeffrey A.,Frazier O.H.
Abstract
The widespread use of continuous-flow left ventricular assist devices for mechanical circulatory support has shown that long-term hemodynamic support is possible, even when a clinical “pulse” cannot be detected. We present the incidental discovery of ventricular fibrillation in 6 alert, hemodynamically stable patients supported only by a continuous-flow device (HeartMate II, n=5; Jarvik 2000, n=1). Ventricular fibrillation was found in 3 patients during routine outpatient follow-up visits and in 3 awaiting discharge from the hospital after device placement. Diagnosis was confirmed by electrocardiographic and echocardiographic studies.
The average duration of mechanical circulatory support before ventricular fibrillation occurred was 221 ± 362 days (range, 5–864 d). All patients were conscious and ambulatory at the time of the arrhythmia. Three patients reported symptoms—primarily fatigue, nausea, and exertional dyspnea—that prompted evaluation. Serum chemistry analysis of blood drawn immediately after diagnosis showed no changes that suggested end-organ dysfunction. Three patients died of unrelated complications an average of 3.9 yr (range, 360–2,270 d) after the event. Two of the remaining 3 patients eventually underwent successful pump explantation, and one is on ongoing support.
Our experience shows that it is possible for patients with continuous-flow left ventricular assist devices to remain hemodynamically stable while in ventricular fibrillation. Additional investigation is needed to determine whether defibrillator settings for these patients should be adjusted to limit delivery of shock therapy.
Publisher
Texas Heart Institute Journal
Subject
Cardiology and Cardiovascular Medicine
Reference12 articles.
1. Ventricular arrhythmias during left ventricular assist device support;Bedi;Am J Cardiol,2007
2. Prolonged sustained ventricular fibrillation without loss of consciousness in patients supported by a left ventricular assist device;Fasseas;Cardiology,2002
3. Left ventricular assist device (LVAD) enables survival during 7 h of sustained ventricular fibrillation;Salzberg;Eur J Cardiothorac Surg,2004
4. Application of a mechanical heart and lung apparatus to cardiac surgery;Gibbon;Minn Med,1954
5. An ideal heart pump with hydrodynamic characteristics analogous to the mammalian heart;Saxton;Trans Am Soc Artif Intern Organs,1960
Cited by
7 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献