Background Accelerometry is an emerging option for real-time evaluation of functional capacity in patients with pulmonary arterial hypertension (PAH). This prospective pilot study assesses the relationship between functional capacity by accelerometry and right ventricular measurements on echocardiography for this high-risk cohort. Methods Patients with PAH were prospectively enrolled and underwent 6-Minute Walk Test and cardiopulmonary exercise testing. They were given a Fitbit, which collected steps and sedentary time per day. Echocardiographic data included right ventricular global longitudinal, free wall, and septal strain; tricuspid regurgitant peak velocity; tricuspid annular plane systolic excursion; tricuspid annular plane systolic velocity; right ventricular myocardial performance index; and pulmonary artery acceleration time. Pairwise correlations were performed. Results The final analysis included 22 patients aged 13 to 59 years. Tricuspid regurgitant peak velocity had a negative correlation with 6-Minute Walk Test (r = −0.58, P = .02), peak oxygen consumption on exercise testing (r = −0.56, P = .03), and average daily steps on accelerometry (r = −0.59, P = .03), but a positive correlation with median sedentary time on accelerometry (r = 0.64, P = .02). Pulmonary artery acceleration time positively correlated with peak oxygen consumption on exercise testing (r = 0.64, P = .002). There was no correlation between right ventricular strain measurements and functional capacity testing. Conclusion In this pilot study, tricuspid regurgitant jet and pulmonary artery acceleration time were the echocardiographic variables that correlated most with accelerometry data. With further echocardiographic validation, accelerometry can be a useful, noninvasive, and cost-effective tool to monitor disease progression in patients with PAH.

Publisher

Texas Heart Institute Journal

Subject

Cardiology and Cardiovascular Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3