PROVISION OF CENTRAL VENOUS ACCESS DURING ALLOGENEIC HAEMATOPOIETIC STEM CELL TRANSPLANTATION

Author:

Spirin M. V.1ORCID,Galstyan G. M.1ORCID,Drokov M. Yu.1ORCID,Kuzmina L. A.1ORCID,Klyasova G. A.1ORCID,Parovichnikova E. N.1ORCID,Savchenko V. G.1ORCID

Affiliation:

1. National Research Center for Hematology

Abstract

Introduction. The transplantation of allogeneic haematopoietic stem cells (allo-HSCT) is impossible without a central venous catheter (CVC).Aim. To determine an optimal approach to providing venous access during allo-HSCT.Materials and methods. This prospective, non-randomised, single-centre study included 146 patients (70 men and 76 women, median age 37 years) who underwent the fi rst allo-HSCT. Prior to conditioning, one of the following CVCs was placed: Hickman or Leonard tunnelled double-lumen silicone catheters (BardAccessSystem); polyurethane non-tunnelled CVCs without (Certofi x Duo, B. Braun) or with an antibacterial coating (Certofi x Protect Duo, B. Braun). The following complications were recorded: early complications, mechanical complications, catheter-associated thrombosis (CAT), catheterrelated bloodstream infections (CRBSI), as well as catheter exit-site and tunnel infections.Results. A total of 320 CVCs were placed (146 prior to allo-HSCT and 174 in the post-transplant period); 259 of the CVCs were non-tunnelled and 61 were tunnelled. Non-tunnelled CVCs were used for 1–123 days (median 22 days), whereas tunnelled CVCs were implanted for 9–621 days (median 146 days). The use of non-tunnelled CVCs was associated with 2.7 % (1.0/1000 catheter days) of mechanical complications and 9 % of CAT (1.4 / 1000 catheter days). The use of tunnelled CVCs was associated with the following complications: accidental removal — 1 (1.6 %), catheter rupture — 4 (6.5 %), CAT — 5 (8.2 %) patients (0.3 / 1000 catheter days); 18 (29.5 %) patients exhibited catheter obstruction, with CVC function being restored in 14 (77.7 %) patients, whereas in 4 (22.3 %) patients the CVC was removed. The incidence of CRBSI associated with non-tunnelled and tunnelled CVCs was 4.4 and 1.5 per 1000 catheter days, respectively. The study revealed no significant differences in the probability of developing CRBSI between non-tunnelled CVCs with and without antibacterial coating (p = 0.298), as well as between non-tunnelled and tunnelled CVCs in the fi rst 28 days after the catheter placement (p = 0.424). The risk of developing CRBSI when using tunnelled CVCs increased after 150 days of use.Conclusion. Allo-HSCT can be performed using any CVC type. Our study revealed no advantages in employing nontunnelled CVCs with an antibacterial coating compared to those having no coating. Tunnelled CVCs (as opposed to nontunnelled ones) provide the opportunity to employ a single catheter throughout the entire transplantation and post-transplant period. It should be noted that tunnelled CVCs should not be used for more than 150 days, since prolonged use of such CVCs significantly increases the risk of infection.Conflict of interest: the authors declare no conflict of interest.Financial disclosure: the study had no sponsorship.

Publisher

National Medical Research Center of Hematology of the Ministry of Health of the Russian Federation

Subject

Hematology

Reference64 articles.

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3