Dosimetry assessment for mobile c-arm: use of badge attached to the equipment

Author:

Alvarez Matheus,Milani Ana Luiza,Pavan Souza Samara,Monteiro Rodrigues Felipe,Fattori Alves Allan Felipe,Jatti de Carvalho Junior Edson,Pina Diana RodriguesORCID

Abstract

The use of fluoroscopy equipment in surgical procedures exposes professionals to ionizing radiation. An important safety aspect is the correct use of personal protective equipment and monitoring of dose levels in workers. In Brazil, the Resolution of the Collegiate Board of Directors (RDC) No. 330/2019 demands the use of individual dosimeter for professionals who exceed the public dose limits. However, when personal dosimeters are not available, the International Atomic Energy Agency (IAEA) recommends attaching a dosimeter to the C-Arm, close to the detector, to estimate the dose received by medical personnel. The objective of this research was to evaluate the levels of exposure in professionals during surgical procedures in the operation room. This analysis was performed by placing OSL dosimeters on the C-arm equipment for eleven months and comparing them with the quantitative values extracted from the equipment in the routine. Two mobile fluoroscopies C-Arm equipment were used in this study. A total of 1231 procedures were evaluated, with a mean dose value of 5.8µSv per procedure. Thus, the maximum number of procedures that the same professional can perform was 140 procedures per day for a staff member considering worker dose limits and 7 procedures per day for staff members using the required protective aprons considering the public dose limits. Although the study shows that the dose limits established by regulatory bodies are above the doses recorded in clinical practice, this situation should not promote false safety in the use of ionizing radiation.

Publisher

Sociedade Brasilieira de Protecao Radiologica - SBPR

Subject

General Medicine

Reference21 articles.

1. BUSHBERG, JERROLD T. The essential physics of medical imaging, 3rd ed. Philadelphia: Wolters Kluwer Health/Lippincott Williams & Wilkins, 2012.

2. ANVISA, Agência Nacional de Vigilância Sanitária, Resolução Da Diretoria Colegiada - RDC Nº 330. 2019, Ministério da Saúde. 23p.

3. (CNEN), Comissão Nacional de Energia Nuclear, Norma CNEN NN 3.01, in Diretrizes Básicas De Proteção Radiológica. 2014.

4. ICRP - International Commission on Radiological Protection The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103. Ann ICRP. 37, 2007. 332p.

5. ABOSALA, A. A Report on Occupational Ionizing Radiation Exposure by an Orthopedic Surgeon in a National Health-care Setting - Clinical Case Perspective. J Orthop Case Rep. 8: p. 81-84, 2018.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3