Effect of Bilayer Nano-Micro Hydroxyapatite on the Surface Characteristics of Implanted Ti-6Al-4V ELI

Author:

Ilhamdi ,Gunawarman ,J. Affi ,O. Susanti ,D. Juliadmi ,D. Oktaviana ,M. Tauhid

Abstract

Ti-6Al-4V ELI is a well-known, popular medical-grade titanium alloy due to its biocompatibility and excellent mechanical properties. However, like other metal implants, it is less bioactive that affects tissue regeneration around the implant, and may lead to implant failure. So, a bioactive substance such as hydroxyapatite (HA) has usually been coated on metal implants to improve its bioactive properties. However, a single layer of HA was reported to be dissolved into body fluid after a long time of exposure in the human body. In this study, bilayer HA was deposited on the surface of screw-type implants made of Ti-6Al-4V ELI through electrophoretic deposition (EPD method. The bottom layer consists of micro-size of HA, and the second layer contains nano-size HA. The suspension contains each micro and nano size of HA powder was homogenized for 1 h followed by sonication for 2 h using a magnetic stirrer. The coating layer was subsequently sintered at 700oC for 1 h. The bilayer-coated screw implant was then implanted into the proximal tibia of health rattus novergicus under proper surgical procedures. Some screws without HA deposition were also implanted into rattus novergicus for comparison. The implanted screws were then taken out via surgery after 2, 3 and 4 weeks, and they were subsequently observed by optical microscope, SEM and XRF. The results showed that organic material is found on each coated specimen, and few HA layer is disintegrated from the surface of the screw. The disintegrated HA remained in the surface of the screw, and the amount of HA increased with increasing implantation time, which indicates the increase of osseointegration between the bone and HA layer. XRF showed a significant difference in Ti and titanium oxide contents on the surface of the coated samples and the non-coted ones, where it is only 0.66%Ti (0.39% TiO2) on the surface of the screw with HA layer and 70%Ti (67% TiO2) for without HA. When TiO2 is formed as a fast self-healing reaction while the screw is exposed to body fluid, the HA acts as an interface against body fluid that may contain aggressive ions. So, HA layer is not only effective against corrosion attack but also inhibits the formation of TiO2 on the implant surface. The coated screws also revealed a strong bonding between the HA layer and the surface of the implant screw. Besides, the ratio between Ca and P elements on the screw surface is in the range of 0.58 – 2.04, which is in the range of bone characteristics.

Publisher

Universiti Malaysia Pahang Publishing

Subject

Mechanical Engineering,Automotive Engineering

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3