Author:
M.A.S. Zainuddin ,Abdullah Muhammad,S. Ahmad ,K.A. Tofrowaih
Abstract
This work presents a performance comparison between a Predictive Functional Control (PFC) and a traditional Proportional Integral Derivative (PID) controller specifically for a cruise control application. The tuning efficacy, constraints handling, and disturbance rejection features of both controllers are analysed by comparing their closed-loop response. A simplified nonlinear vehicle longitudinal dynamics model is derived and utilised as a plant to simulate the control response from a real car. For a fair comparison, both PFC and PID are tuned to achieve the similar desired closed-loop time response. Qualitatively, the results show that PFC provides a better closed-loop response, constraints handling, and disturbance rejection compared to PID. Besides, it is also found that the tuning approach of PFC is more intuitive and practical in nature which can be very handy for the future development of an autonomous cruise control application.
Publisher
Universiti Malaysia Pahang Publishing
Subject
Mechanical Engineering,Automotive Engineering
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献