Thrombectomy aspiration device geometry optimization for removal of blood clots in cerebral vessels

Author:

Talayero C.,Romero G.,Pearce G.,Wong J.

Abstract

A study involving the removal of blood clots in cerebral vessels by aspiration thrombectomy is presented. A robust design for the distal end geometry of a catheter is obtained that, together with adequate suction conditions, could avoid potential damage in the artery or fragmentation the thrombus. The optimization process of the parameters is undertaken by a Design of Experiments (DOE) that has been prepared based on Robust Design theories. In particular, 27 experiments are run for one factor at 9 levels (catheter geometry) and up to 9 factors at 3 levels. The experiments are formulated with virtual models that are solved with computing tools. Co-simulation between Computer Fluid Dynamics (CFD) and Finite Elements Method (FEM) structural analysis was used to obtain the suction conditions and the behavior of the blood clot during the intervention process. By comparing the results of the 27 experiments, the highest values of the suctioning force are obtained for a hole pattern based catheter design, that also gives the lowest risk for clot damage (based on the stress value obtained). Direct aspiration and designs based on conical catheter distal ends, give less robust solutions (results are not stable when the conditions of the environment change). Our study investigated the distance between the catheter and the clot, and it was noted that if the catheter was far from the clot, the suction generated a vessel narrowing and consequent potential damage. Up to 90 kPa could be applied when suctioning at a maximum distance equal to the diameter of the vessel between the distal end of the catheter and the proximal end of the clot. A maximum suctioning force of 0,514N was achieved without damage to the artery or the clot. This research enables us to determine and use the most representative parameters and geometries to be tested in in-vitro and in-vivo experiments. In this virtual study, hypothesizes are assumed with regard to the material properties, but the robustness of the design process allows to expect similar results in future in-vitro and in-vivo tests.

Publisher

Universiti Malaysia Pahang Publishing

Subject

Industrial and Manufacturing Engineering,Mechanical Engineering,Mechanics of Materials,Energy Engineering and Power Technology,Fuel Technology,Computational Mechanics

Cited by 8 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3