Interatrial block and abnormal P-wave electrocardiographic parameters as non-invasive predictors of atrial fibrillation

Author:

Vaikhanskaya T. G.1ORCID,Kaptiukh T. M.1,Kozlov I. D.1ORCID,Frolov A. V.1ORCID

Affiliation:

1. State Institution «Republican Scientific and Practical Centre «Cardiology»»

Abstract

Aim. To identify noninvasive markers of atrial electrical dysfunction and risk of nonvalvular atrial fibrillation (AF) and to develop a predictive mathematical model to estimate the AF risk based on electrocardiographic (ECG) P-wave parameters during sinus rhythm.Methods. The study included 211 patients with cardiovascular pathology (aged median 62 [52; 71] years, 67.8% male, NYHA heart failure class I-III). All patients (follow-up median 45 [26; 67] months) underwent a complex of studies: 12-lead ECG, echocardiography, 24-hour ECG monitoring. Based on surface ECG data during sinus rhythm, parameters of atrial electrical activation were assessed such as Morphology, Voltage and P waves duration (MVP) according to integral analysis by MVP score.Results. During 3.7-year period, 44 (20.8%) patients experienced new-onset sustained AF and 12 (5.69%) patients developed ischemic stroke. As a result of ROC analysis and univariate Cox regression, independent predictors of AF were identified: P-wave prolongation in the DII lead, 3rd degree or advanced interatrial block (aIAB), an increase P-wave terminal force in lead V1 (PTFV1), low-voltage P-wave in the DI lead and сalculated level of abnormal P-wave ≥3 points on the MVP score. Data from multivariate Cox proportional hazards regression analysis confirmed the prognostic significance for three independent predictors of AF: aIAB (hazard ratio (HR) 5.92; 95% confidence interval (CI) [2.48-4.12]; p=0.0001); PTFV1 (HR 1.14; 95% CI [1.04-1.24], p=0.003); low-voltage P-wave in lead DI <0.1 mV (HR 1.03; 95% CI [1.02-1.05]; p=0.0001); and as a result a mathematical model was created to predict AF risk (-2LL =258; χ2=105; p=0.0001). Predictors such as PTFV1 (HR 1.41; 95% CI [1.17-1.72], p=0.0001) and MVP score of abnormal P-waves (HR 1.85; 95% CI [1.27-1.72] 2.70], p=0.001) were associated with a high risk of stroke according to Cox regression model (-2LL= 62.5; χ2=38.4; p <0.001).Conclusion. Complex of ECG markers of atrial electrical dysfunction such as aIAB, PTFV1, level MVP score of abnormal P-wave and low P-wave voltage allows identifying patients at high risk of AF and ischemic stroke.

Publisher

Institute of Cardio Technics - INCART

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Does a complete atrial block exist?;Journal of Arrhythmology;2024-05-31

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3