The change in the position of the esophagus during radiofrequency ablation of the pulmonary veins is minimal according to esophagography

Author:

Bazylev V. V.1ORCID,Kozlov A. V.1ORCID,Durmanov S. S.1ORCID

Affiliation:

1. Federal Center for Cardiovascular Surgery the MH RF

Abstract

Aim. To study the change in the position of the esophagus during radiofrequency ablation of the pulmonary veins (RFA PV) using esophagographyMethods. The period of the study is from August 2022 to January 2023 inclusive. The study is a single-center observational non-randomized study. The study included 191 patients. RFA PV were performed under conscious sedation with dexmedetomidine and fentanyl. The patients were available for verbal contact throughout the operation. After performing a transeptal puncture, esophagography was performed in the LAO 30° projection using 10 ml of Omnipac water-soluble contrast agent (GE Healthcare Ireland). At the end of the operation, esophagography was performed repeatedly. The position of the esophagus was determined relative to the shadow of the spine. Measurements were carried out at three levels: the upper one at the intersection of the esophagus and the roof of the left atrium, the lower one at the intersection with the ring of the mitral valve; the middle level at the middle of the distance between the upper and lower measurements. The width of the contrasted lumen of the esophagus was measured at the same levels. Lateral displacement of the esophagus was defined as the difference in the values of measurements of the position of the lateral and medial boundaries of the esophageal shadow on esophagograms obtained at the beginning and end of the operation.Results. The average lateral displacement of the esophagus was 2.0 ±1.9 mm at the upper level, 3.4±1.6 mm at the middle level and 1.4±1.2 mm at the lower level of the left atrium. There was no significant statistically difference in the change in the position of the esophagus at the beginning and end of the operation (p=0.251, p=0.558, p=0.824, respectively, for the upper, middle and lower measurement levels). The most significant displacement of the esophageal shadow was 5.3 mm. The maximum change in the width of the contrasted lumen of the esophagus was 5.5 mm.Conclusions. According to esophagography with water-soluble contrast, the position of the esophagus during RFA PV does not experience clinically significant changes.

Publisher

Institute of Cardio Technics - INCART

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3