Transcatheter occlusion of the coronary sinus increases radiofrequency ablation lesion size in the left ventricular myocardium: a new approach to improve the efficiency of ventricular tachyarrhythmia substrate destruction

Author:

Korobchenko L. E.1ORCID,Condori Leandro H. I.1ORCID,Vakhrushev A. D.1ORCID,Andreeva E. M.1ORCID,Lebedev D. S.1ORCID,Mikhaylov E. N.1ORCID

Affiliation:

1. FSBI «Almazov National Medical Research Centre» of the Ministry of Health of the Russian Federation

Abstract

The aim. The results of ventricular tachyarrhythmia catheter ablation in patients with structural heart diseases remains to be improved. Both evolution of the arrhythmia substrate and its deep location are the main reasons for standard endocardial ablation limitations. Theoretically, the reduction of myocardial perfusion rate may improve convective heating of the myocardium during radiofrequency (RF) ablation, expanding the volume of damage. The purpose of this study was to assess the effect of coronary sinus (CS) occlusion in order to reduce myocardial perfusion during RF ablation on the volume of myocardial damage.Methods. The study was performed on 13 pigs. Following vascular access accomplishment, a balloon catheter was inserted into the lumen of the CS. A 3.5-mm open-irrigated RF ablation catheter was inserted into the cavity of the left ventricle. RF applications were applied in an alternate order, with and without CS occlusion (power 30 and 40W, application time 40 and 30 s, respectively). Each ablation point was marked on a three-dimensional electroanatomic map. After euthanasia, myocardial lesions were analyzed.Results. The analysis of 50 RF applications was performed (22 with CS occlusion and 28 without CS occlusion). At the same time, 28 applications (13 with occlusion and 15 without occlusion) were performed at a power of 40W, and 22 applications (9 with occlusion and 13 without occlusion) at a power of 30 watts. There was a trend toward the increase in lesion sizes created during CS occlusion. Significantly larger lesions were detected with 40W applications during CS occlusion when compared with open CS applications: depth 11.6±3.9 vs. 8.8±3.8 mm (p=0.04), diameter 11.7±4.6 vs. 8.5±3.9 mm (p=0.03), volume 504.2±499.5 vs. 183.0±157.5 mm3 (p=0.01). Transmural myocardial lesions were more often encountered during applications with CS occlusion with both power settings, 30 and 40W: 68.2% of transmural lesions versus 39.3%; p=0.046.Conclusion. RF applications with a power of 40W and CS occlusion are characterized by greater depth, diameter, and volume of damage, as well as a greater frequency of transmural necrosis. Temporary transcatheter occlusion of CS can be proposed for ablation of ventricular arrhythmia with extended and deep substrate.

Publisher

Institute of Cardio Technics - INCART

Subject

Pharmacology (medical),Cardiology and Cardiovascular Medicine,Emergency Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3