Cardiac contractility modulation therapy in patients with implanted cardiac resynchronization therapy: results of the 2 year follow-up

Author:

Davtyan K. V.1ORCID,Mironova N. A.2ORCID,Chugunov I. A.1ORCID,Gupalo E. M.2ORCID,Topchyan A. G.1ORCID

Affiliation:

1. Federal State Budgetary Institution «National Medical Research Center for Therapy and Preventive Medicine» of Ministry of Health of Russian Federation

2. Federal State Budgetary Institution «National Medical Research Centre of Cardiology named after Academician E.I.Chazov» of Ministry of Health of Russian Federation

Abstract

Aim. Cardiac contractility modulation (CCM) is a device therapy for patients with heart failure with reduced ejection fraction (HFrEF), most of the data on its programming are concerned patients with narrow QRS and of limited follow up. Our aim was to propose programming approach for Optimizer device in setting of wide QRS complex and fragmented ventricular local activation.Methods. We enrolled 11 patients with HFrEF (median age, 8 males, median NYHA class 3) and LBBB-related wide QRS complex, who underwent Optimizer™ device implantation. Three patients got Optimizer™ IV system and eight patients were implanted Optimizer™ Smart. Ten patients were previously implanted with CRT-D due to HFrEF and LBBB; one patient received CRT-D after Optimizer™ implantation.Results. During the implantation procedure ventricular local sense (LS) channel signal fragmentation was detected in all patients. In five patients signal detection was optimized by lead relocation. In six patients LS signal sensitivity limitations were resolved by programming. At two-year follow-up survival 4 patients died of noncardiac causes (1 intracranial hemorrhage, 1 gastrointestinal bleeding and 2 - terminal kidney failure). At 12-month follow-up we observed a non-significant improvement in 6-minute walking distance (300 vs 305, p=0.093), NYHA class (2.75 vs 2, p=0.085), MLHF score (53 vs 42, p=0.109) and left ventricular ejection fraction (LVEF) (30 vs 33.5, p=0.212).Conclusion. CCM system implantation is feasible and safe in patients with HFrEF and LBBB-related wide QRS complex. Device programming maneuvers can resolve the challenges of ventricular local signal detection in these patients.

Publisher

Institute of Cardio Technics - INCART

Subject

Pharmacology (medical),Cardiology and Cardiovascular Medicine,Emergency Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3