Noninvasive activation mapping during the cardiac conductive system pacing

Author:

Medved M. S.1ORCID,Zubarev S. V.1ORCID,Chumarnaya T. V.2ORCID,Bazhutina A. E.2ORCID,Solovyova O. E.2ORCID,Lebedev D. S.1ORCID

Affiliation:

1. FSBI «Almazov National Medical Research Centre» of the MH RF

2. FSBI of Science «Immunology and Physiology Institution of Ural Department of Russian Science Academy»

Abstract

Aim. To identify the features of activation of the right and left ventricles during cardiac conductive system pacing.Methods. There are 2 groups of the study. The cardiac conductive pacing carried in patients of first group. The cardiac conductive pacing not carried in patients of second group. Before and after implantation of the pacemaker, all patients underwent ECG, noninvasive activation mapping using the Amycard software and hardware complex, the width of the QRS, the activation time of the left (LVAT) and right (RVAT) ventricles were determined initially and against the background of pacing. The parameter values are presented in the format: median and interquartile range (Me [25; 75]).Results. The study protocol was performed in 30 patients: first group - 20 patients, second group - 10. The age of the patients was 73 [57; 81] and 71 [63; 75] years, respectively. The value of native QRS complexes in first group was 106 [100; 132] msec, in second group - 144 [109; 155] msec; LVAT 70 [60; 93] msec and 88 [75; 115] msec, respectively; RVAT 62 [50; 74] msec and 85 [67; 117] msec, respectively. There were no statistically significant differences between the groups (p > 0.05) in age, values of native QRS, LVAT, RVAT. The implantable electrode model is identical in both groups. The value of the QRS complex during pacing in first group was 117 [109; 125] msec and 160 [145; 173] msec in second group; LVATp 76 [65; 89] msec and 129 [119; 148] msec, respectively; RVAT 67 [60; 80] msec and 108 [90; 128] msec, respectively. The study revealed statistically significant differences between the two groups of all evaluated parameters against the background of pacing: QRS (p = 0.01), LVAT (p = < 0.01), RVAT (p < 0.01). It should be noted that the initial values and values against the background of pacing of the QRS, LVAT, RVAT complex in patients of group No. 1 did not differ (p > 0.05); in patients of the second group, the values of the QRS, LVAT, RVAT complex initially and against the background of stimulation had significant differences (p = 0.11, p < 0.01 and p = 0.038 respectively).Conclusion. Cardiac conductive system paving is a promising method of cardiac pacing, which allows to achieve activation of the myocardium of the left and right ventricles, which does not differ significantly from activation with a sinus rhythm.

Publisher

Institute of Cardio Technics - INCART

Subject

Pharmacology (medical),Cardiology and Cardiovascular Medicine,Emergency Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3