Experience with various occluder types for endovascular hemodynamic isolation of the left atrium appendage in patients with non-valvular atrial fibrillation

Author:

Pevzner D. V.1ORCID,Merkulov E. V.1ORCID,Arutyunyan G. K.1ORCID,Komarov A. L.1ORCID,Shakhmatova O. O.1ORCID,Ushanova A. M.1ORCID,Merkulova I. A.1ORCID,Davtyan K. V.2ORCID,Chazova I. E.1ORCID

Affiliation:

1. National Medical Research Center of Cardiology

2. National Medical Research Center for Therapy and Preventive Medicine

Abstract

The aim of our study was to evaluate implantation efficacy and safety across various occluder types and to identify factors determining device selection.Methods. This single-site prospective observational study included patients above the age of 40 years with non-valvular atrial fibrillation (AF) and high thromboembolic risk, undergoing endovascular isolation of the left atrium appendage (LAA) with Watchman or Amplatzer Cardiac Plug/Amulet devices. Occluders were implanted to patients without either had contraindications to anticoagulant therapy (ACT) or refused ACT. We evaluated technical aspects of device implantation, short- and long-term outcomes of the intervention over 3 years of follow-up.Results. 90 patients were enrolled in the study (62 into the Watchman arm and 28 into the Amplatzer arm). Interventions were technically successful in 89 cases. In 1 patient (1/90, 1.1%) technical success was not achieved due to device migration (Amplatzer Amulet). The incidence of early (occurring within˂ 24 hours) implantation complications was 0% in the Watchman arm, and 3.6% in the Amplatzer arm (1/28) (р=0.135) (device migration). The cumulative incidence of all in-hospital complications was 11.3% and 14.3%, respectively (р=0.734). No significant differences between arms were found in the incidence of device thrombosis within 90 days post-implantation (3.3% in the Watchman’s arm and 8.3% in the Amplatzer arm, р=0.316). During the observation period, there were no significant differences in comparison groups in the incidence of net clinical efficacy endpoint events (р=0.58). The bleeding rate was 17.7% and 14.3%, respectively, р=0.769. No factors influencing the choice of the device could be identified reliably; however, there was a trend towards Watchman preference for appendage anatomic variants such as broccoli and cactus. Amplatzer was preferred in patients with contraindications to ACT.Conclusion. Implantation of Watchman and Amplatzer Amulet occluders is equally effective and safe in preventing thromboembolism in patients with AF not receiving ACT for various reasons. The individual choice of a device may be influenced by appendage anatomy and indications to occluder implantation.

Publisher

Institute of Cardio Technics - INCART

Subject

Marketing,Organizational Behavior and Human Resource Management,Strategy and Management,Drug Discovery,Pharmaceutical Science,Pharmacology

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3