Air Quality Assessment in Petroleum Flow Station: A Case Study of Oredo Flow Station

Author:

S.B Bukar,H.N. Okonkwo,O. A. Nwaezeapu

Abstract

Air quality is a vital aspect of environmental health and a key determinant of human wellbeing. This study was carried out to assess air quality parameters and noise levels around Oredo Flow Station in Edo State, Nigeria. Parameters measured during the study were temperature, suspended particulate matter (SPM), sulphur dioxide (SO2), nitrogen dioxide (NO2), carbon monoxide (CO) and noise. Each parameter was measured using appropriate equipment. Measurements were done at three points: Point A (300m from the flare site), Point B (200m from the flare site) and Point C (100m from the flare site) and in triplicates with mean values recorded. The result showed that temperature ranged from 28.60±0.3°C to 29.22±0.3°C; SPM ranged from 17.16±3.9 μg/m3 to 60.74±14.6 μg/m3 ; SO2 ranged from 0.01±0.0 ppm to 0.03±0.0 ppm; CO concentrations ranged from 0.03±0.0 ppm to 4.45±1.3 ppm; and VOC concentrations ranged from 0.01±0.0 ppm to 1.87±0.2 ppm. The mean noise levels ranged from 56.24±2.8dB to 87.78±2.8dB. Time-weighted average noise level ranged from 56.2dB to 87.8dB. For all parameters, there was a general decreasing trend in values as distance to the flare site increased indicating that air quality parameters in the area were influenced by gas flaring activities. Recommendations made include routine air quality monitoring, alternative use of natural gas and implementing noise control measures.

Publisher

International Journal of Innovative Science and Research Technology

Reference30 articles.

1. Abulude, F., Fagbayide, S., Akinnusotu, A. and Elemide, A. (2019). Ambient Air Quality Assessment in Nigeria: Challenges and Remedies. In: T. Umar, ed., Multifarious Issues in Nigeria Today: Multidisciplinary Approaches, 1st ed. Akure: Science and Education Development Institute, 124-132.

2. Akpoghelie, J. O., Irerhievwie, G. O., Agbaire, P. O., and Orisaremi, A., (2016). An Assessment of Air Quality in Sub – Urban Cities in Isoko, Delta State Nigeria. Journal of Emerging Trends in Engineering and Applied Sciences (JETEAS) 7(4), 179- 185.

3. Akpomedaye, O. and Okposo, A. M. (2021). Gas Flaring and its Effects around Ogini Flow Station, Ozoro, Delta State, Nigeria. International Research Journal of Modernisation in Engineering Technology and Science, 3(6), 997-1001.

4. Chukwu, M. N. (2022). Gas flaring Effects around Agbada II Flow Station in Igwuruta, Rivers State, Nigeria. University of Thi-Qar Journal of Science, 9(2), 84-89.

5. Giwa, S. O., Nwaokocha, C. N., Kuye, S. I. and Adama, K. O. (2019). Gas flaring attendant impacts of criteria and particulate pollutants: A case of Niger Delta region of Nigeria. Journal of King Saud University-Engineering Sciences, 31(3), 209-217.

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Design and Analysis of Structural Members of the Jib Crane;International Journal of Innovative Science and Research Technology (IJISRT);2024-06-24

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3