The Impact of Open Vs. Closed Blood Collection on Specimen Quality, Health Care Worker Safety, & Work Efficiencies, at a Tertiary Care Centre in South India

Author:

S. Sankar,P.L. Jayalakshmy,Joe Jim,S. Deepa

Abstract

BACKGROUND In the present era of automation, the quality of laboratory specimens is critical towards the delivery of accurate and useful results. The mode of collection of the sample is one such variable. Proper collection and handling of blood samples prevent erroneous results, reduce turnaround time and ensure safety of healthcare workers and patients. The study purpose is to compare open and closed systems of blood collection and the impact of closed collection system in the reduction of pre analytical errors and promoting health care worker safety. METHODS This is a prospective comparative study and it was conducted on blood samples collected in the Outpatient Department of Government Medical College, Kottayam and preanalytical study variables were assessed at Departments of Haematology and Biochemistry. At the beginning of the study, the quality and the quantity of specimen, result accuracies and healthcare safety parameters were assessed for 4778 samples using open blood collection system. This was followed by training of the phlebotomists for closed system of blood collection. The same parameters were studied for another 2508 blood samples collected via closed collection system by the same phlebotomists. The open blood collection system was carried out using non vacuum tubes (Plain and K3 EDTA), 5 ml syringe and 23G needles and closed blood collection system used BD vacutainer (K2 EDTA and serum gel tubes), Eclipse TM safety 22G needles and pronto TM reusable safety holders. The study was conducted from 01-01-2021 to 31-03-2021. RESULTS The specimen quality errors namely fibrin mass, strands, haemolysis, recentrifugation, and insufficient volume in biochemistry lab were significantly reduced with introduction of closed collection system. In haematology lab, closed collection system reduced incidence of clotted sample, insufficient volume accompanied by significant reduction in platelet and WBC differential flags. Closed collection system also reduced occurrence of blood smeared containers and blood spillage on test requisition forms, hence improving safety of health care personnel. CONCLUSIONS The study establishes a significant reduction in pre-analytical errors with closed blood collection system, prevents test cancellation and improved workflow efficiency. KEY WORDS Accuracy, Blood Collection Systems, Errors, Phlebotomist, Preanalytical, Spillage, Variables.

Publisher

Akshantala Enterprises Private Limited

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3