A Three-Dimensional Bioabsorbable Tissue Marker for Volume Replacement and Radiation Planning: A Multicenter Study of Surgical and Patient-Reported Outcomes for 818 Patients with Breast Cancer

Author:

Kaufman Cary S.,Cross Michael J.,Barone Julie L.,Dekhne Nayana S.,Devisetty Kiran,Dilworth Joshua T.,Edmonson David A.,Eladoumikdachi Firas G.,Gass Jennifer S.,Hall William H.,Hong Robert L.,Kuske Robert R.,Patton Brandon J.,Perelson Carol,Phillips Rogsbert F.,Smith Arnold B.,Smith Linda A.,Tafra Lorraine,Lebovic Gail S.

Abstract

Abstract Background Accurate identification of the tumor bed after breast-conserving surgery (BCS) ensures appropriate radiation to the tumor bed while minimizing normal tissue exposure. The BioZorb® three-dimensional (3D) bioabsorbable tissue marker provides a reliable target for radiation therapy (RT) planning and follow-up evaluation while serving as a scaffold to maintain breast contour. Methods After informed consent, 818 patients (826 breasts) implanted with the BioZorb® at 14 U.S. sites were enrolled in a national registry. All the patients were prospectively followed with the BioZorb® implant after BCS. The data collected at 3, 6, 12, and 24 months included all demographics, treatment parameters, and provider/patient-assessed cosmesis. Results The median follow-up period was 18.2 months (range, 0.2–53.4 months). The 30-day breast infection rate was 0.5 % of the patients (n = 4), and re-excision was performed for 8.1 % of the patients (n = 66), whereas 2.6 % of the patients (n = 21) underwent mastectomy. Two patients (0.2 %) had local recurrence. The patient-reported cosmetic outcomes at 6, 12, and 24 months were rated as good-to-excellent by 92.4 %, 90.6 %, and 87.3 % of the patients, respectively and similarly by the surgeons. The radiation oncologists reported planning of target volume (PTV) reduction for 46.2 % of the patients receiving radiation boost, with PTV reduction most commonly estimated at 30 %. Conclusions This report describes the first large multicenter study of 818 patients implanted with the BioZorb® tissue marker during BCS. Radiation oncologists found that the device yielded reduced PTVs and that both the patients and the surgeons reported good-to-excellent long-term cosmetic outcomes, with low adverse effects. The BioZorb® 3D tissue marker is a safe adjunct to BCS and may add benefits for both surgeons and radiation oncologists.

Publisher

Springer Science and Business Media LLC

Subject

Oncology,Surgery

Cited by 16 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3