Author:
Shams Sina,Lippold Kai,Blohmer Jens Uwe,Röhle Robert,Kühn Friedrich,Karsten Maria Margarete
Abstract
Abstract
Background
Sentinel lymph node biopsy after technetium-99 (Tc99) localization is a mainstay of oncologic breast surgery. The timing of Tc99 injection can complicate operating room schedules, which can cause increasing overall costs of care and patient discomfort.
Methods
This study compared 59 patients who underwent breast cancer surgery including sentinel lymph node biopsy. Based on the surgeon’s choice, 29 patients were treated with Tc99, and 30 patients received the iron-based tracer, Magtrace. The primary outcomes were time spent on the care pathway and operating time from commissioning of the probe to removal of the sentinel node. The secondary outcomes were patient pain levels and reimbursement.
Results
The mean time spent on the preoperative breast cancer care pathway was significantly shorter for the Magtrace group (5.4 ± 1.3 min) than for the Tc99 group (82 ± 20 min) (p < 0.0001). The median time from probe usage to sentinel node extirpation was slightly but not significantly shorter in the Magtrace group (5 min; interquartile range [IQR], 3–15 min vs 10 min; IQR, 7–15 min; p = 0.151). Reimbursement and pain levels remained unchanged, and the hospital length of stay was similar in the two groups (Magtrace: 5.1 ± 2.3 days vs Tc99: 4.5 ± 3.2 days).
Conclusions
Magtrace localization shortened the preoperative care pathway and did not affect surgical time or reimbursement. Once established, it could allow for cost reduction and improve patient comfort.
Funder
Sysmex Deutschland GmbH, Norderstedt, Germany
Charité
Publisher