Non-invasive electromagnetic detection of prostate cancer: efficiency analysis

Author:

Chaliy M. E.1ORCID,Afanasyevskaya E. V.2ORCID,Amirkhanyan A. S.2ORCID,Strigunov A. A.1ORCID,Kadysheva A. M.1ORCID,Kolygina E. V.1ORCID,Shurygina A. S.1ORCID,Tivtikyan A. S.1ORCID,Kadrev A. V.1ORCID,Dzitiev V. K.1ORCID,Okhobotov D. A.1ORCID,Sorokin N. I.1ORCID,Kamalov A. A.1ORCID

Affiliation:

1. Lomonosov Moscow State University (Lomonosov University)

2. Lomonosov Moscow State University (Lomonosov University); Istra Regional Clinical Hospital

Abstract

Introduction. Early diagnosis of cancer is one of the most important international strategies. Malignant and healthy tissues differ in the interaction with electromagnetic waves. Pilot studies show a potential perspective for non-invasive analysis of electromagnetic anisotropy in biological tissues.Objective. To assess the diagnostic importance of the electromagnetic detection of prostate cancer (PCa) within the prospective study.Materials & methods. One hundred and twenty-four patients were included to undergo a prostate biopsy, transurethral prostate resection, or radical prostatectomy. The investigators did not have information on their clinical details. Research technique: the probe was applied to the perineal region, turning it in three planes. A reduction of the 465 MHz band below a threshold was fixed and was considered suspect for PCa. The results of electromagnetic evaluation were compared with the findings of a pathomorphological study after biopsy or surgery.Results. Fourty-seven true-positive and 21 true-negative results were detected, 20 false-negative and 46 false-positive (follow-up group as potentially true-positive group). The overall sensitivity was 82%, specificity – 31%. The positive and negative predictive values were 73% and 62%, respectively. The accuracy of the method was 54%.Conclusion. Early PCa stage could be a reason for many false-positive results and low specificity, as a result. PCa detection is significantly reduced with lesions less than 3 mm, therefore patients with false-positive results were placed in the follow-up group. Patients’ examination with the TRIMprob TM («Galileo Avionica» SpA, Torino, Italy) could increase the early PCa detection at the screening. The research is currently ongoing. 

Publisher

Rostov State Medical University

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3