Design and simulation of a multichannel sensing system for liquid refractometry based on integrated photonics
-
Published:2023-12
Issue:6
Volume:47
Page:884-894
-
ISSN:0134-2452
-
Container-title:Computer Optics
-
language:
-
Short-container-title:Computer Optics
Author:
,Zakoyan A.G.,Voronkov G.S., ,Lyubopytov V.S., ,Sultanov A.K., ,Grakhova E.P., ,Kutluyarov R.V.,
Abstract
The paper proposes a new architecture for the photonic laboratory-on-a-chip sensing systems, where multiple sensors based on microring resonators (MRR) are fed by a MRR with low quality factor, working as a spectrum shaper. This architecture enables simultaneous intensity scanning of at least four MRR-based sensors on the silicon-on-insulator platform. We evaluated numerically the system’s sensitivity for various schemes of connecting the sensors and the spectrum shaper. The sensor’s sensitivity was 110 nm/RIU. The sensing system configuration largely determines its sensitivity, which reaches 1980 dB/RIU. The considered architecture may be useful for implementing fully integrated optical lab-on-a-chip structures, as well as distributed multichannel sensing systems.
Publisher
Samara National Research University