Accuracy of implant site preparation in robotic navigated dental implant surgery

Author:

Linn Thu Ya1,Salamanca Eisner1,Aung Lwin Moe1,Huang Ta‐Ko23,Wu Yi‐Fan1ORCID,Chang Wei‐Jen14ORCID

Affiliation:

1. School of Dentistry, College of Oral Medicine Taipei Medical University Taipei Taiwan

2. School of Dentistry Kaohsiung Medical University Kaohsiung Taiwan

3. EPED Incorporation Kaohsiung Taiwan

4. Dental Department, Shuang‐Ho Hospital Taipei Medical University New Taipei City Taiwan

Abstract

AbstractBackgroundModern technological advancements have led to increase in the development of surgical robots in dentistry, resulting in excellent clinical treatment outcomes.PurposeThis study aimed to determine the accuracy of automatic robotic implant site preparation for different implant sizes by correlating planned and posttreatment positions, and to compare the performance of robotic and human freehand drilling.MethodSeventy‐six drilling sites on partially edentulous models were used, with three different implant sizes (Ø = 3.5 × 10 mm, 4.0 × 10 mm, 5.0 × 10 mm). The robotic procedure was performed using software for calibration and step‐by‐step drilling processes. After robotic drilling, deviations in the implant position from the planned position were determined. The angulation, depth, and coronal and apical diameters on the sagittal plane of sockets created by human and robotic drilling were measured.ResultsThe deviation of the robotic system was 3.78° ± 1.97° (angulation), 0.58 ± 0.36 mm (entry point), and 0.99 ± 0.56 mm (apical point). Comparison of implant groups showed the largest deviation from the planned position for 5 mm implants. On the sagittal plane, there were no significant differences between robotic and human surgery except for the 5‐mm implant angulation, indicating similar quality between human and robotic drilling. Based on standard implant measurements, robotic drilling exhibited comparable performance to freehand human drilling.ConclusionsA robotic surgical system can provide the greatest accuracy and reliability regarding the preoperative plan for small implant diameters. In addition, the accuracy of robotic drilling for anterior implant surgery can also be comparable to that of human drilling.

Publisher

Wiley

Subject

General Dentistry,Oral Surgery

Reference40 articles.

Cited by 12 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3